A network engineer is designing cabling infrastructure for a manufacturing facility expansion. The project requires two specific cabling runs: Run 1 is a 75-meter horizontal drop routed through an environmental air plenum space adjacent to high-voltage industrial motors generating severe electromagnetic interference (EMI). Run 2 is a 400-meter inter-building backbone connection between two separate facilities with differing electrical ground potentials.
Which of the following cabling specifications and standards should the engineer select to meet all distance, fire safety, noise immunity, and grounding requirements? (Select TWO.)
- CMP-rated (Plenum) Shielded Twisted Pair (STP) Category 6a cabling for Run 1Answer
- Single-Mode Fiber (SMF) optical cabling with LC connectors for Run 2Answer
- CCMR-rated (Riser) Unshielded Twisted Pair (UTP) Category 6 cabling for Run 1
- DRG-6 coaxial cable terminated with F-type connectors for Run 2
Answer
The network engineer should deploy CMP-rated Shielded Twisted Pair (STP) Category 6a cabling for the horizontal plenum run (Run 1) and Single-Mode Fiber (SMF) optical cabling for the inter-building backbone connection (Run 2).
Deploying CMP-rated Shielded Twisted Pair (STP) Category 6a satisfies the 75-meter length requirement while adhering to strict plenum fire code regulations and insulating data signals against motor-induced EMI. Deploying Single-Mode Fiber (SMF) for the 400-meter inter-building backbone overcomes the 100-meter copper distance limitation and eliminates risk from electrical ground potential differences.
Step-by-Step Solution
Key Concept
Selecting network cable types, plenum ratings, EMI shielding, and fiber optic standards based on environmental and physical limits.