Question

Difficulty: EasyNetwork and Peripheral Cables and Connectors

A field technician is deploying network cables inside an industrial facility where cables will run through ceiling air handling spaces and near heavy machinery generating high electromagnetic interference (EMI). Which TWO cable specifications or construction features should the technician select for this environment? Select TWO.

  1. Shielded Twisted Pair (STP) cabling to mitigate electromagnetic interferenceAnswer
  2. Plenum-rated jacket insulation to comply with building fire safety standardsAnswer
  3. C
    Standard Polyvinyl Chloride (PVC) outer jacketing to prevent smoke accumulation
  4. D
    Unshielded Twisted Pair (UTP) cabling to increase high-frequency signal throughput

Answer

The correct selections are Shielded Twisted Pair (STP) cabling to mitigate EMI and Plenum-rated jacket insulation to comply with building fire codes in air handling spaces.
Shielded Twisted Pair (STP) provides metallic shielding to block electromagnetic interference (EMI) from heavy machinery, while plenum-rated jacket insulation is flame-retardant and releases low smoke, meeting safety requirements for air handling plenum spaces.

Step-by-Step Solution

1
Analyze environmental noise requirements
Industrial machinery generates heavy electromagnetic interference (EMI), requiring Shielded Twisted Pair (STP) cabling rather than Unshielded Twisted Pair (UTP).
STP incorporates metallic foil or braid shielding that blocks noise from external electrical equipment.
2
Analyze environmental space and fire safety requirements
Ceiling air handling spaces are classified as plenum spaces, requiring plenum-rated (CMP) cable jacketing.
Plenum cables resist fire and emit low toxic fumes if burned, whereas PVC cables emit hazardous gases in air circulation spaces.

Key Concept

Cable Shielding and Fire Rating Specifications
Rate this question