Question

Difficulty: Very hardPharmacological and Parenteral Therapies

An oncology client arrives at the outpatient infusion clinic to receive an intravenous antibiotic. The client has an implanted central venous access device (port) that is currently de-accessed. Place the nursing actions for accessing and preparing the port in the correct chronological sequence.

  1. 1Place a surgical mask on both the client and the nurse, and perform hand hygiene.
  2. 2Don sterile gloves and cleanse the skin over the port with chlorhexidine using back-and-forth friction.
  3. 3Allow the cleansed area to air-dry completely without fanning or blotting.
  4. 4Stabilize the port using the non-dominant hand and insert a non-coring needle perpendicular to the septum.
  5. 5Aspirate the attached syringe to check for a blood return to confirm correct needle placement.
  6. 6Flush the port with 10 mL of 0.9% sodium chloride to assess patency and clear the line.

Answer

The correct sequence prioritizes infection control and patient safety: mask/hand hygiene, don sterile gloves and cleanse, allow to air-dry, insert a non-coring needle, aspirate for blood return, and finally flush with saline.
Accessing an implanted port requires strict aseptic technique and safety verification. Masking the client and nurse prevents respiratory droplet contamination. Hand hygiene and sterile gloves are mandatory for central line procedures. Chlorhexidine with friction effectively reduces skin flora, but it must air-dry completely to be bactericidal. A non-coring (Huber) needle is required to prevent damaging the port's silicone septum. Crucially, before injecting any fluids, the nurse must aspirate for a blood return to verify the needle is within the port reservoir and the catheter tip is in the central vasculature. Flushing with saline only occurs after placement is confirmed, ensuring patency and clearing any locking solutions.

Step-by-Step Solution

1
Place a surgical mask on both the client and the nurse, and perform hand hygiene.
Airborne and droplet infection control is established.
Prevents respiratory droplets from contaminating the sterile insertion site.
2
Don sterile gloves and cleanse the skin over the port with chlorhexidine using back-and-forth friction.
The skin is chemically prepared.
Friction helps the chlorhexidine penetrate the epidermal layers to effectively reduce microbial flora.
3
Allow the cleansed area to air-dry completely without fanning or blotting.
The site becomes maximally aseptic.
Chlorhexidine requires adequate drying time to achieve its full bactericidal effect; fanning introduces new pathogens.
4
Stabilize the port using the non-dominant hand and insert a non-coring needle perpendicular to the septum.
The port is successfully accessed.
A non-coring (Huber) needle prevents slicing or damaging the port's self-sealing silicone septum.
5
Aspirate the attached syringe to check for a blood return to confirm correct needle placement.
Placement in the central vasculature is verified.
Aspiration ensures the catheter tip is correctly positioned before any medications or fluids are injected.
6
Flush the port with 10 mL of 0.9% sodium chloride to assess patency and clear the line.
The port is ready for the prescribed antibiotic infusion.
Flushing confirms patency and safely clears any residual concentrated heparin lock solution from the catheter.

Key Concept

Implanted Venous Port (Port-a-Cath) Access Sequence and Central Line Infection Prevention
Rate this question