While troubleshooting a de-energized printed circuit board, a technician measures the resistance across a resistor that remains fully soldered in place. The digital multimeter displays a steady reading of . What is the primary cause of this lower resistance reading?
- AThe circuit must be energized so that the multimeter internal sensing circuit receives sufficient operating voltage.
- The test current from the multimeter is flowing through alternate parallel paths connected across the circuit board.Cevap
- CThe resistor has experienced an internal breakdown and formed a complete electrical short circuit.
- DThe multimeter leads were placed across the component in reverse polarity without zeroing the test leads.
Cevap
The test current from the multimeter is flowing through alternate parallel paths connected across the circuit board.
A digital multimeter measures resistance by injecting a small internal test voltage and measuring the resulting current. When measuring a component that is still soldered into a circuit, that test current splits across the component and any other interconnected parallel branches. Because parallel resistance combinations always result in an equivalent resistance smaller than the smallest branch (), the meter registers a lower value () than the resistor's nominal rating (). To obtain an accurate reading, at least one lead of the component must be disconnected or desoldered.
Adım Adım Çözüm
Anahtar Kavram
In-circuit resistance measurement, component isolation, and parallel path loading