A step-up transformer in a specialized power supply is connected to a source on its primary side. The secondary circuit delivers a current of across a resistive load. If the primary winding has , what is the total number of turns on the secondary winding?
- A
- B
- Cevap
- D
Cevap
The correct answer is . First, determine the secondary voltage using Ohm's Law: . Then, apply the transformer ratio formula , yielding .
Adım Adım Çözüm
Anahtar Kavram
Transformer turns ratio and multi-step AC secondary load calculations