Soru

Zorluk: ZorResistance and Resistivity

A copper feed wire in a naval radar subsystem has a length of 50 m50\text{ m}, a circular cross-sectional diameter of 2.0 mm2.0\text{ mm}, and a measured DC resistance of 0.27 Ω0.27\ \Omega. During maintenance, this line is replaced with an alloy wire that has a resistivity 4.04.0 times that of copper, a total length of 75 m75\text{ m}, and a diameter of 3.0 mm3.0\text{ mm}. What is the electrical resistance of the replacement wire in ohms?

Cevap: 0.72 ohms

Cevap

The electrical resistance of the replacement wire is 0.72 ohms.
Electrical resistance is given by the formula R=ρLA=4ρLπd2R = \rho \frac{L}{A} = \frac{4\rho L}{\pi d^2}. Comparing the replacement wire to the original: resistivity increases by a factor of 4.04.0, length increases by a factor of 7550=1.5\frac{75}{50} = 1.5, and cross-sectional area increases by a factor of (3.02.0)2=2.25\left(\frac{3.0}{2.0}\right)^2 = 2.25. Combining these factors gives an overall resistance change factor of 4.0×1.52.25=83\frac{4.0 \times 1.5}{2.25} = \frac{8}{3}. Multiplying the baseline resistance of 0.27 Ω0.27\ \Omega by 83\frac{8}{3} gives exactly 0.72 Ω0.72\ \Omega.

Adım Adım Çözüm

1
Relate electrical resistance to material resistivity and conductor dimensions.
R=ρLA=4ρLπd2R = \rho \frac{L}{A} = \frac{4\rho L}{\pi d^2}
Resistance is directly proportional to resistivity and length, and inversely proportional to cross-sectional area (which depends on the square of the diameter).
2
Determine the relative scaling factors for resistivity, length, and diameter.
Resistivity factor =4.0= 4.0; Length factor =7550=1.5= \frac{75}{50} = 1.5; Diameter factor =3.02.0=1.5= \frac{3.0}{2.0} = 1.5
Proportional scaling allows direct calculation without calculating intermediate microscopic values.
3
Calculate the combined scaling factor for resistance.
R2R1=ρ2ρ1×L2L1×(d1d2)2=4.0×1.5×(11.5)2=4.01.5=83\frac{R_2}{R_1} = \frac{\rho_2}{\rho_1} \times \frac{L_2}{L_1} \times \left(\frac{d_1}{d_2}\right)^2 = 4.0 \times 1.5 \times \left(\frac{1}{1.5}\right)^2 = \frac{4.0}{1.5} = \frac{8}{3}
Area scales quadratically with diameter, so diameter increase reduces resistance by a factor of 1.52=2.251.5^2 = 2.25.
4
Calculate the final resistance of the replacement wire.
R2=0.27 Ω×83=0.72 ΩR_2 = 0.27\ \Omega \times \frac{8}{3} = 0.72\ \Omega
Multiplying the original resistance by the overall scaling factor yields the new total resistance.

Anahtar Kavram

Dependence of electrical resistance on resistivity, conductor length, and cross-sectional area

Alternatif Yöntem

Calculate the resistivity of copper first using ρCu=R1A1L1=0.27×π(0.001)250≈1.696×10−8 Ω⋅m\rho_{\text{Cu}} = \frac{R_1 A_1}{L_1} = \frac{0.27 \times \pi (0.001)^2}{50} \approx 1.696 \times 10^{-8}\ \Omega\cdot\text{m}. Then calculate ρalloy=4.0×ρCu≈6.786×10−8 Ω⋅m\rho_{\text{alloy}} = 4.0 \times \rho_{\text{Cu}} \approx 6.786 \times 10^{-8}\ \Omega\cdot\text{m}, and compute R2=ρalloy×75π(0.0015)2=0.72 ΩR_2 = \frac{\rho_{\text{alloy}} \times 75}{\pi (0.0015)^2} = 0.72\ \Omega.
Tahmini Süre:1m 30s