A 24 V24\text{ V} DC bridge circuit consists of two parallel branches connected between a constant +24 V+24\text{ V} DC supply rail and ground:
- Left branch: Resistor R1=1.0 kΩR_1 = 1.0\,\text{k}\Omega connected in series with resistor R2=1.0 kΩR_2 = 1.0\,\text{k}\Omega to ground, with Test Point A (VAV_A) located between them.
- Right branch: Resistor R3=1.0 kΩR_3 = 1.0\,\text{k}\Omega connected in series with resistor R4=1.0 kΩR_4 = 1.0\,\text{k}\Omega to ground, with Test Point B (VBV_B) located between them.

Under normal operation, the total current drawn from the supply is 24 mA24\text{ mA}, and VA=VB=12.0 VV_A = V_B = 12.0\text{ V}. During diagnostic testing of a faulty unit, a technician measures the following values:
- VA=12.0 VV_A = 12.0\text{ V} (measured with respect to ground)
- VB=24.0 VV_B = 24.0\text{ V} (measured with respect to ground)
- Total current drawn from the 24 V24\text{ V} source = 36 mA36\text{ mA}

Which of the following circuit faults accounts for these diagnostic readings?

  1. A
    An open circuit fault in resistor R4R_4
  2. B
    A short circuit fault across resistor R4R_4
  3. A short circuit fault across resistor R3R_3Cevap
  4. D
    An open circuit fault in resistor R3R_3

Cevap

A short circuit fault across resistor R3R_3
A short circuit across resistor R3R_3 bypasses the upper resistor, placing Test Point B directly at the +24 V+24\text{ V} supply rail. This leaves only resistor R4R_4 (1.0 kΩ1.0\,\text{k}\Omega) in the right branch, increasing the right branch current to 24 V/1.0 kΩ=24 mA24\text{ V} / 1.0\,\text{k}\Omega = 24\text{ mA}. Combining this with the normal 12 mA12\text{ mA} from the left branch produces the exact measured total current of 36 mA36\text{ mA}.

Adım Adım Çözüm

1
Analyze the operational status and current of the left branch.
Left branch current Ileft=12 mAI_{\text{left}} = 12\text{ mA}.
Since VA=12.0 VV_A = 12.0\text{ V} across R2=1.0 kΩR_2 = 1.0\,\text{k}\Omega, the left branch is normal and draws Ileft=24 V/(1.0 kΩ+1.0 kΩ)=12 mAI_{\text{left}} = 24\text{ V} / (1.0\,\text{k}\Omega + 1.0\,\text{k}\Omega) = 12\text{ mA}.
2
Determine the current flowing through the right branch under fault conditions.
Right branch current Iright=24 mAI_{\text{right}} = 24\text{ mA}.
Subtract the normal left branch current from the measured total current: Iright=Itotal−Ileft=36 mA−12 mA=24 mAI_{\text{right}} = I_{\text{total}} - I_{\text{left}} = 36\text{ mA} - 12\text{ mA} = 24\text{ mA}.
3
Calculate the effective resistance of the right branch and evaluate voltage drop across components.
Rright=1.0 kΩR_{\text{right}} = 1.0\,\text{k}\Omega, with 0 V0\text{ V} dropped across R3R_3.
Rright=Vsource/Iright=24 V/24 mA=1.0 kΩR_{\text{right}} = V_{\text{source}} / I_{\text{right}} = 24\text{ V} / 24\text{ mA} = 1.0\,\text{k}\Omega. Since R4R_4 is 1.0 kΩ1.0\,\text{k}\Omega and VB=24.0 VV_B = 24.0\text{ V}, the full 24 V24\text{ V} drops across R4R_4, meaning R3R_3 has 0 V0\text{ V} drop and zero resistance (a direct short circuit).

Anahtar Kavram

Distinguishing between open and short circuit faults using branch voltage and total current analysis