Hospital airborne infection isolation rooms are designed with negative air pressure relative to adjoining corridors, ensuring that air flows inward rather than outward when doors open. Exhaust air from these rooms is drawn through high-efficiency particulate air (HEPA) filters before being discharged directly outdoors. If the dedicated exhaust fan suffers a mechanical drop in ventilation capacity while the central supply air continues to operate at normal output, the pressure differential reverses. Under such conditions, airborne pathogens are forced into public hospital hallways.

Based on the passage, which of the following can be logically concluded about airborne infection isolation rooms?

  1. A
    Hospital corridors must operate secondary sterilization systems to counteract routine airflow reversals between adjacent rooms.
  2. B
    Airborne pathogens escaping into public hallways cause the dedicated exhaust fan to suffer a drop in ventilation capacity.
  3. Effective containment requires the exhaust system to extract air at a rate greater than the supply system introduces it.Cevap
  4. D
    Discharging exhaust air through high-efficiency particulate air filters prevents pressure reversals during mechanical fan failures.

Cevap

Effective containment requires the exhaust system to extract air at a rate greater than the supply system introduces it.
The passage establishes that when exhaust capacity drops while supply air remains constant, the pressure differential reverses and pushes room air into hallways. This directly implies that maintaining inward air pressure depends on the exhaust system extracting more air than the supply system introduces.

Adım Adım Çözüm

1
Analyze the conditions that govern air pressure differences in the passage.
The text states that negative pressure keeps air flowing inward, but when exhaust ventilation drops below the rate of incoming supply air, the pressure differential reverses and forces air outward.
Identifying the relationship between airflow balance and pressure direction is necessary to deduce the operational rule.
2
Deduce the necessary requirement for maintaining inward airflow.
Since supply air exceeding exhaust air creates positive outward pressure, sustaining negative inward pressure requires the exhaust rate to exceed the supply rate.
Connecting the failure condition to standard operation yields the logical deduction governing room containment.

Anahtar Kavram

Deducing necessary operational constraints from described mechanical relationships and failure states.