During a pre-trip walkaround inspection of an air-braked commercial vehicle parked on level ground with the wheels chocked and parking brakes released, a driver inspects the foundation brake assemblies and mechanical linkages. Which of the following observations indicates a safety defect that requires mechanical adjustment or repair before operating the vehicle?
- AThe pushrod does not move at all when pulled by hand while the parking spring brakes remain fully applied.
- The manual slack adjuster pushrod moves more than 1 inch from the brake chamber when pulled firmly by hand.Cevap
- CThe friction lining thickness on the drum brake shoes measures 3/8 inch with no oil or grease contamination.
- DThe angle between the pushrod and slack adjuster arm forms approximately 90 degrees when the service brakes are fully applied.
Cevap
The condition indicating a safety defect requiring repair is when the manual slack adjuster pushrod moves more than 1 inch from the brake chamber when pulled firmly by hand.
When checking manual slack adjusters on an S-cam foundation brake assembly, the vehicle must be parked on level ground with the wheels chocked and parking brakes released. Under manual pull with a tool or hand, pushrod free play should not exceed approximately 1 inch. Travel greater than 1 inch indicates the foundation brake is out of adjustment, which compromises stopping distance and requires immediate mechanical adjustment.
Adım Adım Çözüm
Anahtar Kavram
Foundation Brake Inspection Tolerances and Pushrod Free Play Limits
Tahmini Süre:1m 0s