Soru

Zorluk: ZorExpansion Cards and Power Supplies

A network administrator is assembling a virtualization host server containing multi-port network adapter expansion cards and high-speed storage accelerators. The host system components exhibit the following peak power requirements under full load:

- Processor (CPU): 190 W190\text{ W} peak draw
- Quad-port 10GbE PCIe expansion card: 35 W35\text{ W}
- PCIe NVMe storage accelerator card: 75 W75\text{ W}
- Motherboard, memory modules, and cooling system: 110 W110\text{ W} constant
- Solid-state drive array (4 drives total): 10 W10\text{ W} combined constant

To ensure operational stability and maintain peak efficiency, company guidelines require that the total peak power consumption does not exceed 75%75\% of the Power Supply Unit (PSU) maximum rated wattage output.

What is the minimum power supply capacity, in Watts (W\text{W}), required for this server configuration?

Cevap: 560 W

Cevap

The minimum power supply capacity required is 560 W560\text{ W}.
The total peak power draw of all components is 190 W+35 W+75 W+110 W+10 W=420 W190\text{ W} + 35\text{ W} + 75\text{ W} + 110\text{ W} + 10\text{ W} = 420\text{ W}. Since the system must not exceed 75%75\% (0.750.75) of the PSU's total capacity, the required capacity is 420 W0.75=560 W\frac{420\text{ W}}{0.75} = 560\text{ W}.

Adım Adım Çözüm

1
Sum the maximum peak wattage of all individual components to determine total peak system power draw.
Total peak draw = 190 W+35 W+75 W+110 W+10 W=420 W190\text{ W} + 35\text{ W} + 75\text{ W} + 110\text{ W} + 10\text{ W} = 420\text{ W}.
Accurate power sizing requires considering peak power consumption rather than average or idle draw.
2
Divide the total peak system draw by the maximum allowed load percentage (0.750.75).
Calculated minimum capacity = 420 W0.75=560 W\frac{420\text{ W}}{0.75} = 560\text{ W}.
Restricting continuous peak system draw to 75%75\% of rated PSU capacity leaves a 25%25\% operating headroom, maintaining power conversion efficiency and avoiding overload shutdowns.

Anahtar Kavram

Power supply unit (PSU) wattage calculation and safety headroom planning
Tahmini Süre:2m 0s
Bu soruyu puanla