A network technician is terminating custom Category 6 unshielded twisted-pair (UTP) Ethernet cables to connect client desktop computers to wall jacks. The existing network infrastructure strictly adheres to the ANSI/TIA-568B wiring standard across all patch panels and wall outlets. Which of the following requirements must the technician follow to ensure proper physical layer connectivity for these straight-through connections? (Select TWO)
- Terminate both ends of each cable using the T568B color coding sequence.Cevap
- Position the white/orange wire at Pin 1 and the solid orange wire at Pin 2 of the RJ45 connector.Cevap
- CTerminate one end using T568A and the opposite end using T568B to enable switch communication.
- DPosition the white/green wire at Pin 1 and the solid green wire at Pin 2 of the RJ45 connector.
Cevap
The correct requirements are to terminate both ends of each cable using the T568B color sequence and to place the white/orange wire at Pin 1 and the solid orange wire at Pin 2.
For a standard workstation-to-switch connection in an environment standardized on ANSI/TIA-568B, straight-through cables must be used. This requires terminating both ends with the T568B scheme, where Pin 1 is white/orange and Pin 2 is solid orange.
Adım Adım Çözüm
Anahtar Kavram
T568A and T568B Ethernet Wiring Pinout Standards