A network administrator is troubleshooting an existing Category 6 UTP cabling run between a floor switch and a wall outlet. Although a basic wiremapper confirms full pin-to-pin continuity and proper TIA/EIA 568B wire map alignment, connected devices experience frequent Frame Check Sequence (FCS) errors and link degradation during heavy traffic. Which of the following diagnostic tools should the administrator use to locate the exact position of the physical cable damage along the run?
- Time-Domain Reflectometer (TDR)Cevap
- BTone generator and inductive probe
- COptical Power Meter (OPM)
- DLoopback plug
Cevap
Time-Domain Reflectometer (TDR)
A Time-Domain Reflectometer (TDR) transmits electrical pulses along metallic copper conductors and measures signal reflections caused by impedance discontinuities. By measuring the round-trip time of the reflected wave, the TDR accurately calculates the distance to cable kinks, breaks, or severe NEXT/crosstalk points.
Adım Adım Çözüm
Anahtar Kavram
Selecting copper cabling diagnostic tools for distance-to-fault analysis
Tahmini Süre:1m 0s