Soru

Zorluk: OrtaPharmacological Therapies

A practical nurse is preparing to administer a mixed dose of intermediate-acting (NPH) and short-acting (Regular) insulin to a client with diabetes mellitus. Arrange the following steps in the correct chronological order for mixing these insulins in a single syringe.

  1. 1Clean the rubber stoppers of both insulin vials with alcohol swabs.
  2. 2Inject an amount of air equal to the prescribed dose into the NPH insulin vial.
  3. 3Inject an amount of air equal to the prescribed dose into the Regular insulin vial.
  4. 4Invert the Regular insulin vial and withdraw the prescribed dose into the syringe.
  5. 5Insert the needle into the NPH insulin vial and withdraw the prescribed dose.

Cevap

The correct sequence for mixing insulins is: clean both vials, inject air into the NPH vial, inject air into the Regular vial, draw up the Regular insulin, and finally draw up the NPH insulin.
When mixing short-acting (Regular) and intermediate-acting (NPH) insulin, the correct sequence ensures that the fast-acting insulin is not contaminated with the longer-acting insulin. The standard mnemonic is 'clear before cloudy.' After cleaning the vials, air is injected into the NPH vial first, followed by air into the Regular vial. The Regular (clear) insulin is drawn up first while the needle is already in the vial. Finally, the NPH (cloudy) insulin is drawn up to complete the exact total dose.

Adım Adım Çözüm

1
Clean the rubber stoppers of both insulin vials with alcohol swabs.
The stoppers are disinfected.
Maintains aseptic technique before inserting needles into the vials.
2
Inject an amount of air equal to the prescribed dose into the NPH insulin vial.
Pressure is equalized in the NPH vial.
Prevents a vacuum, making it easier to withdraw medication later. This is done first because the needle has not touched any insulin yet.
3
Inject an amount of air equal to the prescribed dose into the Regular insulin vial.
Pressure is equalized in the Regular vial.
Prepares the vial for immediate withdrawal of insulin.
4
Invert the Regular insulin vial and withdraw the prescribed dose into the syringe.
The short-acting insulin is drawn into the syringe.
Clear (Regular) insulin is drawn up first so that the vial is not contaminated with cloudy (NPH) insulin, which could alter the rapid action of future doses drawn from the Regular vial.
5
Insert the needle into the NPH insulin vial and withdraw the prescribed dose.
The total mixed dose is gathered in the syringe.
Cloudy (NPH) insulin is drawn up last. Care must be taken not to inject any Regular insulin into the NPH vial.

Anahtar Kavram

Safe Medication Administration: Mixing Insulins (Clear before Cloudy)
Bu soruyu puanla