Soru

Zorluk: Çok zorErgonomics and Safe Use of Equipment

A healthcare team in a rehabilitation unit is tasked with moving an immobile, bariatric client from a standard hospital bed to a reinforced cardiac chair using a ceiling-mounted mechanical lift. The client's medical history includes a right total hip arthroplasty (THA) performed 48 hours ago, a continuous intravenous (IV) infusion, and intermittent agitation. To ensure optimal biomechanics and equipment safety during this high-risk maneuver, which interventions must the assigned practical nurse (PN) implement? Select all that apply.

  1. Adjust the bed height to the practical nurse's waist level and lower the head of the bed as flat as the client tolerates before positioning the sling.Cevap
  2. B
    Delegate the physical operation of the ceiling lift to an assistive personnel (AP) and leave the room to gather wound care supplies during the transfer.
  3. Maintain an abduction wedge between the client's lower extremities while attaching the uncrossed leg straps of the sling to the lift's spreader bar.Cevap
  4. D
    Apply soft wrist restraints to the client to prevent them from grabbing the lift straps or dislodging their intravenous (IV) line while suspended.
  5. E
    Flex the client's right hip to 110 degrees to create sufficient clearance for sliding the lower loops of the sling underneath the thighs.
  6. Verify that both the ceiling lift motor and the specific fabric sling being used have a safe working load (SWL) that exceeds the client's current documented weight.Cevap

Cevap

The correct actions are adjusting the bed to waist height while flattening it, maintaining an abduction wedge with uncrossed sling straps, and verifying the safe working load of all lift components.
Safe mechanical transfers for complex clients require a multi-faceted approach. Adjusting the bed height and angle optimizes caregiver biomechanics. Using uncrossed straps with an abduction wedge adheres to vital total hip arthroplasty (THA) precautions while using the equipment. Finally, verifying the safe working load (SWL) for both the motor and the sling is a mandatory safety check for bariatric clients to prevent equipment failure.

Adım Adım Çözüm

1
Evaluate the environmental and equipment safety requirements.
The nurse confirms the lift and sling weight capacities exceed the bariatric client's weight.
Preventing equipment failure is the first step in a safe mechanical transfer.
2
Prepare the environment for optimal ergonomics.
The bed is raised to waist level and the head of the bed is flattened.
This minimizes lumbar flexion and rotational strain on the nursing staff during the manual rolling phase of sling placement.
3
Integrate post-operative precautions into the equipment use.
An abduction wedge is maintained, the hip is not flexed past 90 degrees, and the sling straps remain uncrossed.
Standard lifting techniques must be modified to protect the recent total hip arthroplasty from dislocation.
4
Manage client behavior using least restrictive measures.
The nurse remains at the bedside to monitor the IV and redirect the agitated client without using restraints.
Nursing presence ensures continuous safety monitoring, prohibiting the delegation of this complex transfer.

Anahtar Kavram

Safe operation of mechanical lifting equipment requires integrating principles of body mechanics, surgical precautions, equipment load verification, and continuous nursing supervision.
Bu soruyu puanla