A nurse is preparing to draw a blood specimen from a client's multi-lumen central venous catheter (CVC). A continuous intravenous infusion of 0.9% sodium chloride is currently running through a different lumen of the catheter. Arrange the following steps in the correct chronological order to obtain the blood sample safely and prevent laboratory result contamination.
- 1Pause the continuous intravenous infusion on the other lumen for at least 1 to 2 minutes.
- 2Scrub the needleless connector of the designated sampling lumen with an antiseptic swab.
- 3Flush the sampling lumen to verify patency, then withdraw and discard 5 to 10 mL of blood.
- 4Attach a new sterile syringe and withdraw the required volume of blood for the laboratory specimen.
- 5Flush the sampling lumen with 10 to 20 mL of 0.9% sodium chloride and restart the paused infusion.
Cevap
The correct sequence is to first pause the active infusion, then scrub the hub, verify patency and discard the dead space fluid, draw the actual sample, and finally flush the line and restart the infusion.
The correct sequence ensures patient safety, prevents central line-associated bloodstream infections (CLABSI), and guarantees the integrity of the laboratory specimen. Pausing other infusions is the critical first step to prevent hemodilution. Aseptic technique (scrubbing the hub) must precede any line access. A discard sample is necessary to remove the fluid sitting in the catheter's dead space before obtaining the actual diagnostic sample. Finally, the line must be flushed to prevent clotting, and the paused infusion must be restarted.
Adım Adım Çözüm
Anahtar Kavram
Central Venous Catheter (CVC) Blood Specimen Collection (Discard Method)