An electronics technician is bench-testing a de-energized two-position rotary selector switch using a digital multimeter set to the low-resistance continuity function. With the switch set to Position 1, the meter connected across the common terminal and output terminal 1 displays with an audible tone. When the switch is turned to Position 2, the meter across the common terminal and output terminal 1 continues to display , while testing across the common terminal and output terminal 2 displays (over limit). What specific switch fault do these multimeter readings indicate?
- AThe common terminal insulator has broken down into a conductor, creating an open circuit on all switch positions.
- The internal contacts for Position 1 are welded or shorted closed, while the contacts for Position 2 have failed open.Answer
- CThe meter is reading residual circuit voltage, which forces the resistance display to read zero ohms regardless of contact position.
- DThe switch is functioning normally because a reading of indicates zero resistance and continuous current flow.
Answer
The internal contacts for Position 1 are welded or shorted closed, while the contacts for Position 2 have failed open.
A reading of with an audible tone confirms a closed, continuous electrical path. When the rotary switch is moved to Position 2, output terminal 1 should disconnect and display ; because it remains at , the Position 1 contacts are welded or shorted closed. Simultaneously, output terminal 2 should establish continuity in Position 2; showing indicates an open circuit where contacts failed to close.
Step-by-Step Solution
Key Concept
Interpreting multimeter resistance and continuity values ( vs. ) to diagnose internal short-circuit and open-circuit defects in multi-position switches.
Estimated Time:1m 15s