While assembling a wiring harness, a technician prepares a 16 AWG stranded copper wire. The technician accidentally places the wire into the 20 AWG notch of a precision wire stripper and closes the handles to strip the insulation. What physical damage occurs to the wire, and what electrical problem does this create in the circuit?
- AThe notch is too large for the wire, compressing the insulation jacket without cutting through to expose the conductor.
- The undersized notch severs outer conductor strands, reducing the effective cross-sectional area and causing localized heating under electrical load.Cevap
- CThe friction from stripping alters the atomic structure of the PVC jacket, turning the surrounding insulation into a conductive path.
- DThe nicked copper strands form an immediate short circuit within the single wire, dropping circuit resistance to zero.
Cevap
The undersized notch severs outer conductor strands, reducing the effective cross-sectional area and causing localized heating under electrical load.
Because American Wire Gauge numbers are inversely proportional to wire diameter, a 20 AWG opening is significantly smaller than a 16 AWG conductor core. When the stripper closes, the blades cut through the insulation and slice into the outer copper strands of the conductor. This reduction in the wire's cross-sectional area increases electrical resistance at that point, which can cause excessive heat dissipation ( losses) and mechanical failure under vibration.
Adım Adım Çözüm
Anahtar Kavram
AWG Gauge Calibration and Conductor Integrity in Wire Stripping
Tahmini Süre:1m 30s