Soru

Zorluk: ZorMultimeter: Voltage and Current Measurement

An electronics technician is setting up a digital multimeter (DMM) to perform several diagnostic checks on a circuit test bench. Match each measurement task to its correct meter input jack, dial setting, and circuit connection method.

  • Measuring a low 18 mA18\text{ mA} direct current flowing through a transistor bias networkRed lead in mA/μA\text{mA}/\mu\text{A} jack, black in COM\text{COM}, dial on DC mA\text{DC mA}, connected in series with the opened circuit
  • Checking for standard 120 VRMS120\text{ V}_{\text{RMS}} AC line voltage at a power receptacleRed lead in V/Ω\text{V}/\Omega jack, black in COM\text{COM}, dial on ACV (∼V)\text{ACV}~(\sim\text{V}), connected in parallel across the terminals
  • Measuring a heavy 7.5 A7.5\text{ A} direct current drawn by a DC motor drive circuitRed lead in 10A10\text{A} high-current jack, black in COM\text{COM}, dial on 10A DC10\text{A DC}, connected in series with the opened circuit
  • Verifying a steady 24 V24\text{ V} DC potential difference across a filtering load resistorRed lead in V/Ω\text{V}/\Omega jack, black in COM\text{COM}, dial on DCV (=V)\text{DCV}~(=\text{V}), connected in parallel across the component

Cevap

Match small DC current (18 mA18\text{ mA}) with the mA/μA\text{mA}/\mu\text{A} jack in series; match 120 V120\text{ V} AC line voltage with the V/Ω\text{V}/\Omega jack on ACV\text{ACV} in parallel; match heavy DC current (7.5 A7.5\text{ A}) with the dedicated 10A10\text{A} jack in series; match 24 V24\text{ V} DC potential difference with the V/Ω\text{V}/\Omega jack on DCV\text{DCV} in parallel.
Correct multimeter configuration requires matching three parameters: (1) connection topology (parallel for voltage, series for current), (2) input terminal selection (standard V/Ω\text{V}/\Omega for voltage, low-current mA/μA\text{mA}/\mu\text{A} for values under 400 mA400\text{ mA}, and separate 10A10\text{A} terminal for high current), and (3) function selection matching waveform type (DC vs. AC).

Adım Adım Çözüm

1
Determine connection topology based on measurement quantity (Voltage vs. Current)
Voltmeters must always be connected in parallel across components, while ammeters must always be placed in series by breaking the circuit path.
Voltmeters have high internal input impedance (>10 MΩ>10\text{ M}\Omega) to prevent loading, whereas ammeters have near-zero internal resistance to allow current flow.
2
Select input jacks based on expected signal magnitude and function
Voltage readings use the V/Ω\text{V}/\Omega and COM\text{COM} jacks. Current below 400 mA400\text{ mA} uses the mA/μA\text{mA}/\mu\text{A} jack, while high current (7.5 A7.5\text{ A}) requires the separate 10A10\text{A} high-current terminal.
Exceeding the current rating of the low-current jack will immediately blow the internal protective fuse.
3
Select dial settings based on waveform type (AC vs. DC)
Use ACV\text{ACV} for 120 VRMS120\text{ V}_{\text{RMS}} utility power, DCV\text{DCV} for 24 V24\text{ V} filtered direct potential, DC mA\text{DC mA} for 18 mA18\text{ mA}, and 10A DC10\text{A DC} for 7.5 A7.5\text{ A}.
Setting an AC mode on a DC signal or vice versa leads to erroneous readings or reading zero due to average vs. RMS rectification filtering.

Anahtar Kavram

Multimeter Lead Placement, Jack Selection, and Dial Configuration
Tahmini Süre:2m 0s
Bu soruyu puanla