A technician is designing a control system operated by a single manual toggle switch. When the switch is actuated, it must simultaneously disconnect an existing 12 V DC cooling fan and connect a separate, electrically isolated 120 V AC warning beacon to power. Which switch configuration is the minimum requirement to control both isolated circuits in opposite states with a single mechanical actuator?
- ADouble-Pole, Single-Throw (DPST) switch
- BSingle-Pole, Double-Throw (SPDT) switch
- Double-Pole, Double-Throw (DPDT) switchCevap
- DSingle-Pole, Single-Throw (SPST) switch
Cevap
Double-Pole, Double-Throw (DPDT) switch
The Double-Pole, Double-Throw (DPDT) configuration provides two electrically separate poles (required for isolating the 12 V DC and 120 V AC systems) and two throws per pole. This allows Pole 1 to open the 12 V DC fan circuit while Pole 2 simultaneously closes the 120 V AC beacon circuit under a single mechanical toggle.
Adım Adım Çözüm
Anahtar Kavram
Switch Pole and Throw Nomenclature and Electrical Isolation
Tahmini Süre:1m 15s