Soru

Zorluk: ZorExpansion Cards and Power Supplies

A system administrator is sizing a replacement power supply unit (PSU) for a CAD workstation. The internal components have the following continuous power specifications:

- CPU: 105 W105\text{ W}
- PCIe Graphics Card: 280 W280\text{ W}
- PCIe Sound & Capture Cards: 35 W35\text{ W} total
- Motherboard, RAM, and Storage Drives: 40 W40\text{ W} total

To account for brief GPU transient power excursions, a 35%35\% power overhead must be applied specifically to the graphics card TDP. Additionally, to ensure hardware longevity and system stability, the final total system peak draw must not exceed 80%80\% of the power supply's rated capacity (requiring a 20%20\% safety headroom margin).

What is the minimum recommended PSU wattage rating required for this workstation?

  1. 700 W700\text{ W}Cevap
  2. B
    600 W600\text{ W}
  3. C
    500 W500\text{ W}
  4. D
    460 W460\text{ W}

Cevap

The minimum recommended PSU wattage rating is 700 W700\text{ W}.
The correct option (700 W700\text{ W}) properly factors in the GPU's 35%35\% transient power spike (280 W×1.35=378 W280\text{ W} \times 1.35 = 378\text{ W}), resulting in a combined peak system draw of 558 W558\text{ W}. Accounting for the mandated 20%20\% safety headroom margin (558/0.80=697.5 W558 / 0.80 = 697.5\text{ W}) dictates selecting at least a 700 W700\text{ W} rated power supply unit.

Adım Adım Çözüm

1
Calculate the adjusted peak draw for the GPU including the 35% transient allowance.
Adjusted GPU Power=280 W×1.35=378 W\text{Adjusted GPU Power} = 280\text{ W} \times 1.35 = 378\text{ W}
Modern graphics cards exhibit short-duration power spikes above their rated TDP during intensive workloads.
2
Sum all system component power draws to determine the total peak power requirement.
Total Peak Power=105 W (CPU)+378 W (GPU)+35 W (Expansion Cards)+40 W (System)=558 W\text{Total Peak Power} = 105\text{ W} \text{ (CPU)} + 378\text{ W} \text{ (GPU)} + 35\text{ W} \text{ (Expansion Cards)} + 40\text{ W} \text{ (System)} = 558\text{ W}
All components draw from the power supply simultaneously during peak operational load.
3
Apply the 20% safety headroom margin requirement (total load 80%\le 80\% of PSU capacity).
Minimum Required PSU Capacity=558 W0.80=697.5 W\text{Minimum Required PSU Capacity} = \frac{558\text{ W}}{0.80} = 697.5\text{ W}
Operating a PSU below 80% capacity prevents thermal degradation, avoids unexpected shutdowns, and maximizes power conversion efficiency.
4
Select the next available standard commercial PSU wattage rating.
Select 700 W700\text{ W} PSU (or 750 W750\text{ W} if 700 W700\text{ W} is unavailable).
Power supplies are manufactured in discrete wattage tiers.

Anahtar Kavram

Power Supply Unit (PSU) sizing, component TDP summation, GPU transient spike allowances, and safety headroom margins.
Bu soruyu puanla