When preparing electrical conductors, standard multi-gauge wire strippers provide separate calibrated stripping notches for 'SOLID' and 'STRANDED' wire of the same American Wire Gauge (AWG) size. What is the primary physical reason that stranded wire requires a different stripping notch size than solid wire of the identical gauge?
- AStranded wire insulation is manufactured with thicker thermal polymers, requiring deeper cutting blade penetration to slice through.
- BSolid wire conductors conduct electrical current only along their outer skin, requiring the stripping blade to lightly score the copper.
- Stranded conductors contain air gaps between the bundled wires, giving them a slightly larger total outer diameter than solid conductors of the identical gauge.Cevap
- DStranded wire requires the notch blades to crimp and bite into the outer strands to twist them tightly together during removal.
Cevap
Stranded conductors contain air gaps between the bundled wires, giving them a slightly larger total outer diameter than solid conductors of the identical gauge.
American Wire Gauge (AWG) ratings are based on total cross-sectional copper area. Because multiple round strands leave voids (air gaps) when bundled together, a stranded conductor has a slightly larger overall diameter than a solid conductor of the same gauge. Consequently, wire strippers feature dedicated, slightly larger notches for stranded wire to avoid severing or nicking the outer strands.
Adım Adım Çözüm
Anahtar Kavram
Conductor Geometry and Wire Stripper Notch Sizing