Zorluk: OrtaMultimeter: Voltage and Current Measurement

An electronics technician is testing various circuits under operating conditions. Which multimeter dial setting, input jack configuration, and connection method on the right correctly matches each measurement task on the left?

  • Measuring direct current (8 A8\text{ A}) supplied to an active 12 V12\text{ V} automotive cooling fanRed lead in 10 A10\text{ A} jack, dial set to DC A\text{DC A}, meter inserted in series with the opened power line
  • Measuring line potential difference across an energized 120 V120\text{ V} alternating-current line filterRed lead in V/Ω\text{V}/\Omega jack, dial set to AC V\text{AC V}, meter connected in parallel across the line terminals
  • Measuring low direct current (15 mA15\text{ mA}) passing through a sensor reference circuitRed lead in mA/μA\text{mA}/\mu\text{A} jack, dial set to DC A\text{DC A}, meter inserted in series with the opened signal line
  • Measuring steady direct-current voltage drop across an operational 24 V24\text{ V} solenoid coilRed lead in V/Ω\text{V}/\Omega jack, dial set to DC V\text{DC V}, meter connected in parallel across the solenoid terminals

Cevap

1. High DC current (8 A8\text{ A}) matches red lead in 10 A10\text{ A} jack, DC A\text{DC A} dial, connected in series. 2. AC line voltage (120 V AC120\text{ V AC}) matches red lead in V/Ω\text{V}/\Omega jack, AC V\text{AC V} dial, connected in parallel. 3. Low DC current (15 mA15\text{ mA}) matches red lead in mA/μA\text{mA}/\mu\text{A} jack, DC A\text{DC A} dial, connected in series. 4. DC voltage drop (24 V DC24\text{ V DC}) matches red lead in V/Ω\text{V}/\Omega jack, DC V\text{DC V} dial, connected in parallel.
Each multimeter measurement requires three matching conditions: correct input jack, matching dial mode (AC/DC and quantity), and proper circuit hookup. For high direct current (8 A8\text{ A}), the red probe must occupy the 10 A10\text{ A} jack and be inserted in series with the cooling fan. For alternating voltage (120 V AC120\text{ V AC}), the red probe must occupy the V/Ω\text{V}/\Omega jack, dial set to AC V\text{AC V}, connected in parallel across the filter. For low direct current (15 mA15\text{ mA}), the red probe must be in the mA/μA\text{mA}/\mu\text{A} jack and inserted in series. For direct voltage (24 V DC24\text{ V DC}), the red probe uses the V/Ω\text{V}/\Omega jack, dial set to DC V\text{DC V}, connected in parallel across the solenoid.

Adım Adım Çözüm

1
Differentiate between voltage and current measurement topologies
Voltmeters have high internal impedance and must be connected in parallel across components; ammeters have very low internal resistance and must be connected in series by breaking the circuit path.
Connecting an ammeter in parallel creates a short circuit, while placing a voltmeter in series creates an unintended open/high resistance in the branch.
2
Determine input jack and dial settings for current measurements based on expected amperage magnitude
The 8 A8\text{ A} fan draw exceeds standard milliampere fuses (200–400 mA200\text{--}400\text{ mA}), requiring the unfused or heavy-fused 10 A10\text{ A} jack and DC A\text{DC A} mode. The 15 mA15\text{ mA} sensor signal fits within the high-resolution mA/μA\text{mA}/\mu\text{A} jack and DC A\text{DC A} mode.
Overloading low-current input jacks blows the meter's internal protective fuse.
3
Determine input jack and dial settings for voltage measurements based on waveform type
The 120 V120\text{ V} alternating-current line filter requires the V/Ω\text{V}/\Omega jack and AC V\text{AC V} function. The 24 V24\text{ V} DC solenoid drop requires the V/Ω\text{V}/\Omega jack and DC V\text{DC V} function.
Both voltage measurements utilize the high-impedance V/Ω\text{V}/\Omega jack connected in parallel across the component, but the selector dial must match the signal's electrical nature (AC vs. DC).