An electronics technician needs to measure the DC voltage drop across an active indicator lamp assembly using a manual-ranging digital multimeter (DMM). What is the correct chronological sequence of steps to perform this measurement safely and obtain the most accurate reading?
- 1Insert the black test lead into the COM jack and the red test lead into the V/Ω input jack.
- 2Rotate the selector dial to the DC voltage (DCV) function and choose the highest available voltage range.
- 3Place the meter test probes in parallel across the terminals of the operating indicator lamp.
- 4Gradually lower the selector dial range setting until the reading provides the highest decimal resolution without showing an overload (OL) indicator.
Cevap
The proper sequence starts with inserting the leads into the COM and V/Ω jacks, setting the dial to the DC voltage mode at the highest range, connecting the probes in parallel across the component, and finally stepping down the range setting for maximum display resolution.
Measuring voltage safely and accurately requires connecting test leads to the COM and V/Ω terminals, selecting the DC voltage mode at the highest range to prevent overload, probing across the component in parallel, and then reducing the range to gain the highest resolution reading.
Adım Adım Çözüm
Anahtar Kavram
Digital Multimeter DC Voltage Measurement Procedure and Range Selection