Tüm alıştırma soruları

3551 soru

Soru 1941Soru

An IT technician discovers a corporate workstation actively communicating with a known malicious command-and-control server on the internet. To follow proper CompTIA incident response guidelines and preserve evidence integrity, in what order should the technician execute the following actions?

Öğeleri doğru sıraya koymak için sürükleyin

Cevabı ve açıklamayı göster

Cevap

The correct order of incident response and evidence preservation steps is: 1) Report the security incident immediately to the designated incident response team and management, 2) Isolate the workstation from the network by disconnecting the network cable and disabling Wi-Fi, 3) Capture the volatile system memory (RAM) while the machine remains powered on, and 4) Fill out a chain of custody log and place the seized physical storage drive into a tamper-evident anti-static bag.
Standard operational procedures specify that security incidents must first be reported to proper authorities. Next, the technician must isolate the compromised system from the network to stop active communication without powering down the machine. Once isolated, volatile memory (RAM) must be collected before system state changes. Finally, chain of custody logs are filled out as physical evidence is packaged and handed off.

Adım Adım Çözüm

1
Report the incident through proper organizational escalation channels.
The incident handling protocol is officially initiated with appropriate management awareness.
Reporting ensures that incident response procedures begin promptly and authorization is granted for further intervention.
2
Isolate the compromised system from local and wide area networks.
Active command-and-control traffic is severed without shutting down the system.
Immediate containment protects other network assets from infection and halts data exfiltration.
3
Perform volatile evidence capture (RAM collection).
Volatile artifacts like running processes, decrypted contents, and socket details are saved.
RAM is highly volatile and must be acquired while the system is live before non-volatile drives are removed or powered off.
4
Complete chain of custody documentation and secure physical evidence.
Legal defensibility and evidence tracking are established with verified timestamps and signatures.
Chain of custody forms account for evidence possession, transfers, and secure physical storage.

Anahtar Kavram

Incident Response Life Cycle and Order of Volatility in Evidence Handling
Soru 1942Soru

A field surveyor uses a specialized GIS mapping application on an enterprise iOS tablet to collect spatial terrain data. During operation, the application frequently stops responding, causing thermal throttling and accelerated battery discharge on the device. Following CompTIA troubleshooting methodology, in what sequence should the technician perform the following steps, ordered from least invasive to most invasive?

Öğeleri doğru sıraya koymak için sürükleyin

Cevabı ve açıklamayı göster

Cevap

The proper troubleshooting order from least invasive to most invasive is: 1) Force close the application, 2) Restart (soft reset) the mobile device, 3) Install application and OS updates, 4) Reinstall the application, and 5) Perform a factory reset.
CompTIA troubleshooting methodology dictates progressing from the least disruptive action to the most disruptive action. Force closing the application is the quickest, least invasive step. If the problem persists, soft resetting the device clears shared system memory. Installing updates fixes software bugs. Reinstalling the app replaces corrupted files, and performing a factory reset is the final, most invasive step.

Adım Adım Çözüm

1
Terminate the affected application process.
Clears transient application lockups without impacting other services or device uptime.
Always begin troubleshooting at the least invasive layer closest to the problem.
2
Restart the operating system (soft reset).
Flushes system memory and restarts system services.
If force quitting fails, restarting the device resolves lower-level OS memory leaks or stuck background tasks.
3
Update software packages (app and OS).
Applies developer bug fixes and system optimization patches.
Ensures the issue is not caused by a known code bug before modifying application installations.
4
Remove and reinstall the application.
Replaces app binaries and refreshes local configuration stores.
More invasive step that clears persistent app-specific file corruption.
5
Execute a factory reset.
Wipes all local data and returns OS to default clean state.
Most invasive measure, reserved as a last resort when OS corruption or system-wide failure persists.

Anahtar Kavram

Least-invasive to most-invasive mobile OS troubleshooting sequence
Soru 1943Soru

An enterprise systems engineer is preparing a formal change request to migrate an organization's central Identity and Access Management (IAM) directory server to a high-availability cloud infrastructure. The engineer has already detailed the business purpose, defined the technical scope, evaluated potential operational risks, and established a backout procedure using virtual machine snapshots. Which of the following additional elements must be included in the change documentation before presenting it to the Change Advisory Board (CAB) for authorization?

Cevabı ve açıklamayı göster

Cevap: An end-user notification plan specifying expected service downtime and communication channels.

Cevap

An end-user notification plan specifying expected service downtime and communication channels is the required element missing from the change documentation.
A complete change management request must include the purpose, scope, risk analysis, plan for change, rollback/backout plan, and end-user notification plan before being submitted to the Change Advisory Board (CAB) for approval. Communicating scheduled downtime and expectations to impacted users is a critical requirement of the change management lifecycle.

Adım Adım Çözüm

1
Analyze the core change management components already completed in the scenario.
The engineer has completed the purpose, scope, risk analysis, and rollback (backout) plan.
Identifying what has been completed isolates which essential CompTIA change management phase is still absent.
2
Evaluate the remaining standard requirements for a formal change request proposal.
Standard ITIL/CompTIA change management process requires: Purpose, Scope, Risk Analysis, Plan for Change, End-User Notification, Rollback Plan, and CAB Approval.
End users and business stakeholders must be notified in advance regarding when service maintenance will occur and how workflows might be impacted.
3
Select the required missing component prior to CAB submission.
The end-user notification plan must be included in the change proposal prior to formal CAB review and approval.
CAB approval relies on knowing that business stakeholders have been properly notified of scheduled downtime.

Anahtar Kavram

Change Management Processes - Required Documentation Elements
Soru 1944Soru

A technician is configuring a newly deployed network multifunction device (MFD) on a central print server for a graphic design department. Users report that when printing complex vector graphics and high-resolution layout files using the current PCL 6 driver, custom font styles are substituted and intricate vector paths distort. Which driver configuration change should the technician make on the print server to resolve this issue?

Cevabı ve açıklamayı göster

Cevap: Switch the print driver associated with the shared printer object to a PostScript (PS) driver.

Cevap

Switch the print driver associated with the shared printer object to a PostScript (PS) driver.
PostScript (PS) is a page description language developed specifically for graphic design, vector graphics, and high-fidelity publishing. Switching the driver on the shared MFD object to a PostScript driver allows vector shapes and typography to render accurately without unwanted substitutions or distortions.

Adım Adım Çözüm

1
Analyze the reported symptom and printing environment requirements.
Identified that vector graphics and custom typography are failing to render accurately when processed by the default PCL 6 driver.
Printer Command Language (PCL) is designed for general office document efficiency, whereas PostScript (PS) is engineered specifically for precise vector rendering and graphic object fidelity.
2
Select the appropriate driver type for graphic design workloads.
Changing the driver model on the print server to a PostScript (PS) driver ensures graphic application rendering commands are interpreted directly using native PostScript vector commands.
Installing and selecting a PostScript driver resolves vector path distortion and prevents font substitution errors.

Anahtar Kavram

Selecting and configuring appropriate printer drivers (PCL vs PostScript) based on application and rendering requirements.
Soru 1945Soru

A user's workstation is assigned a static IP address of 192.168.4.15/24192.168.4.15/24. The user can successfully ping other local computers on the 192.168.4.0/24192.168.4.0/24 network segment, but cannot reach external internet addresses such as 1.1.1.11.1.1.1 by IP address. Other devices on the same local subnet can access external networks without issue. Which of the following network settings is most likely missing or misconfigured on the workstation?

Cevabı ve açıklamayı göster

Cevap: Default Gateway

Cevap

The Default Gateway setting is missing or misconfigured on the workstation.
The default gateway serves as the access point or router interface that forwards packets from the local subnet to external networks. Because the workstation can communicate with devices on its own subnet (192.168.4.0/24192.168.4.0/24) but cannot route traffic to remote IP addresses such as 1.1.1.11.1.1.1, the missing or incorrect Default Gateway address is the root cause.

Adım Adım Çözüm

1
Analyze local vs. remote network connectivity results
Successful local pings confirm Layer 1 and Layer 2 network access as well as correct local subnet IP configuration (192.168.4.15/24192.168.4.15/24).
Traffic staying within the 192.168.4.0/24192.168.4.0/24 network does not require a router.
2
Evaluate why direct IP requests to remote destinations (1.1.1.11.1.1.1) fail
Destinations outside the local subnet require packets to be forwarded to a local router (the default gateway).
If the default gateway IP is omitted or incorrectly set, the workstation cannot route packets outside 192.168.4.0/24192.168.4.0/24.

Anahtar Kavram

Default Gateway Configuration and IP Routing Boundaries
Soru 1946Soru

A network technician is documenting standard firewall port rules for secure management and messaging applications. Match each network protocol on the left with its default port and primary operational role on the right.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

LDAPS
IMAPS
SNMP
SFTP

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

LDAPS pairs with TCP Port 636; IMAPS pairs with TCP Port 993; SNMP pairs with UDP Port 161; SFTP pairs with TCP Port 22.
Each protocol correctly aligns with its standard port assignment and primary use case: LDAPS uses TCP 636 for secure directory services, IMAPS uses TCP 993 for secure email retrieval, SNMP uses UDP 161 for device monitoring, and SFTP uses TCP 22 for SSH-based file transfer.

Adım Adım Çözüm

1
Identify the port and protocol for directory service access
LDAPS utilizes TCP port 636 to provide secure access to Active Directory and LDAP services.
Standard LDAP operates unencrypted on TCP port 389, whereas LDAPS secures communication over TCP port 636.
2
Identify the port and protocol for secure mail retrieval
IMAPS operates on TCP port 993.
Unencrypted IMAP uses TCP port 143, while IMAPS adds SSL/TLS encryption over TCP port 993.
3
Identify transport protocol and port for network device monitoring
SNMP uses UDP port 161 to poll network devices for status and telemetry.
SNMP communication relies on connectionless UDP transport on port 161 (with SNMP traps sent to UDP port 162).
4
Identify secure file transfer protocol operating over SSH
SFTP uses TCP port 22.
Unlike FTPS (TCP 989/990) or plain FTP (TCP 20/21), SFTP leverages Secure Shell on TCP port 22.

Anahtar Kavram

Standard TCP/UDP Port Numbers and Protocol Roles
Tahmini Süre:1m 30s
Soru 1947Soru

During a scheduled infrastructure migration, an IT specialist must coordinate with department leaders whose teams will experience temporary application downtime. In what order should the specialist execute the communication steps to maintain professional interaction standards from initial outreach through project completion?

Öğeleri doğru sıraya koymak için sürükleyin

Cevabı ve açıklamayı göster

Cevap

The correct sequence begins with a professional, jargon-free initial greeting and explanation, followed by active listening to address schedule concerns. Next, clear expectations and approval are established prior to work. During the outage, status updates are provided. Finally, service restoration is verified with stakeholders and documented in the ticketing system.
The correct order follows standard CompTIA customer interaction guidelines: establish initial rapport with clear language, practice active listening to address concerns, set transparent expectations and secure consent, provide ongoing communication during implementation, and complete the process by verifying customer satisfaction and updating documentation.

Adım Adım Çözüm

1
Initiate communication with a proper greeting and clear, jargon-free explanation.
Stakeholders understand the scope of the upcoming work without confusion.
Professional communication starts with establishing rapport and clarity.
2
Practice active listening to understand customer concerns.
Business scheduling impacts are identified and accommodated.
Understanding user needs takes priority before finalizing implementation schedules.
3
Set clear expectations and obtain authorization.
Mutual agreement is reached regarding outage timelines and deliverables.
Prevents misunderstandings and ensures proper authorization before changes occur.
4
Maintain progress updates during system maintenance.
Department heads remain informed of progress and timeline adherence.
Proactive updates prevent unnecessary anxiety during service downtime.
5
Verify customer satisfaction and log details in the ticketing system.
Service functionality is validated and complete history is recorded.
Ensures resolution completeness and administrative compliance.

Anahtar Kavram

Professional Communication and Customer Service Life Cycle
Soru 1948Soru

An IT support technician is handling a service desk incident for a departmental file server that experienced an unexpected service disruption. Place the standard IT service desk workflow steps in the correct sequence from initial intake to final ticket closure.

Öğeleri doğru sıraya koymak için sürükleyin

Cevabı ve açıklamayı göster

Cevap

The correct order of standard ticketing lifecycle steps is: 1) Log the incoming incident with initial details and assign a ticket ID and priority. 2) Perform initial triage, gather logs, and document diagnostic findings. 3) Implement corrective action and record resolution details. 4) Contact the representative to test access and verify resolution. 5) Record root cause analysis and mark the ticket status as Closed.
The standard ticketing workflow follows a structured lifecycle: ticket creation/categorization, triage and diagnostic logging, implementation of the resolution, end-user verification, and final administrative documentation with ticket closure. Placing these steps in sequence ensures complete auditability and adheres to standard IT service management practices.

Adım Adım Çözüm

1
Identify the initial ticketing phase
Ticket Creation and Categorization
An incident must first be logged into the ITSM framework with initial user details, symptoms, and priority assignment before work begins.
2
Identify the investigation phase
Triage and Diagnostics
Once logged, the technician investigates the system, collects logs, and records diagnostic notes in the ticket.
3
Identify the remediation phase
Resolution Implementation
The technician applies the fix to resolve the root cause or fault and updates work notes.
4
Identify the validation phase
User Verification
Before closing a ticket, best practices dictate contacting the affected party to verify service restoration.
5
Identify the final administrative phase
Root Cause Documentation and Ticket Closure
After user confirmation, final notes regarding root cause are logged and the status is changed to Closed.

Anahtar Kavram

IT Service Desk Ticket Lifecycle and Workflow Management
Tahmini Süre:1m 30s
Soru 1949Soru

A desktop technician is servicing an electrophotographic (EP) laser printer that produces printed pages where toner is clearly visible and correctly positioned, but it easily smudges and wipes off the paper surface when touched. The technician has already verified that the paper type matches printer driver specifications and replaced the toner cartridge without resolving the issue. Which component is most likely failing to operate properly?

Cevabı ve açıklamayı göster

Cevap: Fuser assembly

Cevap

The fuser assembly is responsible for applying heat and pressure to permanently bond toner to paper fibers.
The fuser assembly uses intense heat and mechanical pressure to melt the plastic resin inside toner powder, permanently bonding it to the paper fibers. When the heating lamp or pressure roller fails, toner remains resting loosely on top of the paper, leading to severe smudging when touched.

Adım Adım Çözüm

1
Analyze symptom details from the scenario
Toner prints in the correct location but smudges easily off the page upon touch.
This indicates successful image development and transfer, but a failure during the bonding/fusing phase.
2
Evaluate the function of electrophotographic (EP) components
The fuser assembly operates at high temperatures (approx. 180°C–200°C) with pressure rollers to melt toner resin into the paper.
If the heating element or pressure rollers in the fuser malfunction, toner stays un-fused on the surface.
3
Determine the necessary repair action
Replace the fuser assembly (or maintenance kit containing the fuser).
Replacing the fuser restores proper heat and pressure application.

Anahtar Kavram

EP Laser Printing Fusing Process and Fuser Assembly Function
Soru 1950Soru

A network technician is tasked with installing horizontal Ethernet cabling above suspended ceiling tiles across an office building. The open space above the ceiling tiles is actively used by the building's HVAC system as an environmental air return. Which of the following cable jacket ratings must the technician use to meet building safety codes?

Cevabı ve açıklamayı göster

Cevap: CMP (Plenum-rated)

Cevap

CMP (Plenum-rated) cabling is required because it uses fire-resistant materials that produce minimal smoke and non-toxic fumes when exposed to fire in environmental air spaces.
The correct answer specifies CMP (Plenum-rated) cable. Spaces used for air circulation in heating and air conditioning systems are designated as plenum spaces. CMP cable jackets are specifically engineered with fluorinated ethylene propylene (FEP) or specialized low-smoke PVC that resists combustion and does not emit dangerous toxic fumes if burned.

Adım Adım Çözüm

1
Identify the environmental space characteristics from the scenario.
The installation area is a drop-ceiling space used as an HVAC environmental air return (plenum space).
Air return spaces circulate air throughout the building, so smoke or toxic fumes originating here would spread quickly.
2
Determine the fire rating requirements for the identified space.
Building safety codes mandate CMP (Communications Multipurpose Cable, Plenum) rated jacket insulation.
CMP jackets are coated with Teflon or special low-smoke PVC compounds to minimize flame spread and toxic gas production.

Anahtar Kavram

Plenum vs. Non-Plenum Cable Jacket Fire Ratings
Soru 1951Soru

A system technician is specifying internal storage components for a workstation hardware deployment. The system motherboard supports various drive form factors, interface protocols, and keying configurations. Which of the following statements correctly describe storage interfaces and form factor specifications? (Select TWO.)

Geçerli olan tümünü seçin

Cevabı ve açıklamayı göster

Cevap: M.2 solid-state drives with M-key edge connectors can utilize up to four PCIe lanes for high-throughput NVMe protocol storage.; SATA Revision 3.0 interfaces cap theoretical maximum throughput for connected storage drives at 6 Gbps.

Cevap

M.2 SSDs utilizing M-key pin configurations support up to four PCIe lanes for NVMe storage, and SATA Revision 3.0 specifies a maximum theoretical data transfer rate of 6 Gbps.
M.2 drives keyed with M-key edge pinouts accommodate up to four PCIe lanes (PCIe x4), which provides the bus bandwidth necessary for NVMe performance. Furthermore, SATA Revision 3.0 is standardized at a maximum interface data rate of 6 Gbps.

Adım Adım Çözüm

1
Evaluate M.2 physical keying standards and bus lane support.
M-key M.2 drives use pins 59-66 and support PCIe x4, whereas B-key drives use pins 12-19 and support up to PCIe x2 or SATA speeds.
Correctly matching the M.2 keying format to bus lanes ensures maximum available throughput for high-performance storage.
2
Analyze standard SATA controller protocol bandwidth limitations.
SATA Revision 3.0 provides a maximum bus speed limit of 6 Gbps.
Understanding interface limits prevents bottlenecking expectations when specifying drive speeds.
3
Distinguish between physical M.2 form factors and underlying logical protocols.
Inserting a SATA-based M.2 drive into an M.2 slot will not increase its throughput to NVMe levels because the drive's controller remains bound by SATA protocol constraints.
Form factor (M.2) does not alter the inherent protocol limits (SATA vs. NVMe) of the drive controller.

Anahtar Kavram

M.2 Keying & Interface Standards (SATA III vs. PCIe NVMe)
Soru 1952Soru

A user reports that while navigating websites, additional unwanted windows containing advertisements automatically open on top of the active web browser page. Which of the following browser features should a technician enable to prevent these windows from appearing?

Cevabı ve açıklamayı göster

Cevap: Enable the pop-up blocker feature

Cevap

Enable the pop-up blocker feature
Enabling the browser's pop-up blocker directly targets script-driven advertisement windows that open automatically, suppressing unwanted secondary windows from launching over active content.

Adım Adım Çözüm

1
Identify the reported symptom
Unwanted advertisement windows opening automatically over the active web page.
Websites frequently execute scripts designed to launch secondary pop-up windows for promotional content.
2
Select the appropriate browser security setting
Enabling the browser's built-in pop-up blocker.
Pop-up blockers monitor script behavior and suppress unauthorized secondary windows or tabs from opening.

Anahtar Kavram

Web Browser Pop-Up Blocker Security Settings
Tahmini Süre:45s
Soru 1953Soru

A desktop support technician is servicing a Windows workstation that experiences repeated Stop Error (BSOD) crashes immediately after a third-party device driver was automatically updated. The system is unstable in standard Windows mode. Which TWO of the following actions should the technician perform to restore system stability and repair corrupted system files?

Geçerli olan tümünü seçin

Cevabı ve açıklamayı göster

Cevap: Boot the system into Safe Mode and use Device Manager to roll back the recently updated device driver.; Run DISM /Online /Cleanup-Image /RestoreHealth prior to executing sfc /scannow in an elevated command prompt.

Cevap

The technician should boot into Safe Mode to roll back the bad driver using Device Manager, and run DISM /Online /Cleanup-Image /RestoreHealth before running sfc /scannow to fix any system file corruption.
Rolling back the driver in Safe Mode resolves instability caused by the bad third-party update. Running DISM prior to SFC restores the component store image first, ensuring SFC has clean system files to repair corruption.

Adım Adım Çözüm

1
Boot into Safe Mode and access Device Manager.
System boots with essential drivers, allowing stable navigation to open Device Manager and select Driver Roll Back on the faulty device.
Safe Mode prevents third-party drivers from executing, stabilizing the OS so driver management can be safely performed.
2
Open an elevated Command Prompt and execute DISM /Online /Cleanup-Image /RestoreHealth.
The Windows Component Store image is verified and repaired using Windows Update or local repair sources.
DISM must repair the component store first so SFC has a valid repository to pull replacement files from.
3
Execute sfc /scannow in the elevated Command Prompt.
Protected system files are scanned, and corrupted files are replaced using clean versions from the component store.
SFC repairs actual operating system files once the component store payload is confirmed healthy.

Anahtar Kavram

Driver Rollback and Sequential SFC/DISM Repair Order
Tahmini Süre:1m 30s
Soru 1954Soru

A systems administrator for a global e-commerce enterprise is establishing security baseline controls for databases storing payment transaction history and European customer profiles. To maintain strict compliance with both PCI-DSS and GDPR regulations during routine data maintenance and archival, which of the following operational practices MUST the administrator implement? (Select TWO.)

Geçerli olan tümünü seçin

Cevabı ve açıklamayı göster

Cevap: Apply industry-standard cryptographic encryption to payment cardholder data (CHD) and personal data both in transit across public networks and at rest in backup repositories.; Establish technical workflows to sanitize and permanently remove European Union customer records upon verified request under the right to be forgotten.

Cevap

The administrator must encrypt cardholder and personal data both at rest and in transit, and establish automated technical workflows to erase customer personal data upon valid GDPR right-to-be-forgotten requests.
The correct operational practices are applying strong cryptographic encryption to cardholder data and PII at rest and in transit, and setting up workflows to permanently erase EU customer data upon request under GDPR. PCI-DSS mandates encryption for cardholder data across storage and public network transmissions, while GDPR enforces technical data security (Article 32) and data erasure rights (Article 17).

Adım Adım Çözüm

1
Analyze regulatory scope for PCI-DSS data protection requirements.
PCI-DSS requires safeguarding Cardholder Data (CHD) through robust encryption during storage and transit, while explicitly banning the retention of Sensitive Authentication Data (SAD/CVV) after authorization.
Protecting cardholder data limits exposure to credit card fraud and maintains compliance with payment processor frameworks.
2
Analyze regulatory scope for GDPR data subject rights and storage limitation.
GDPR requires pseudonymization/encryption of PII, adherence to storage minimization (retaining data no longer than necessary), and honoring data erasure (right to be forgotten) requests.
EU residents maintain legal ownership of their personal data rights under GDPR standards.
3
Select valid operational controls matching both regulations.
Implementing strong encryption for CHD/PII at rest and in transit, alongside automated data erasure procedures, fulfills both compliance directives.
These controls directly satisfy PCI-DSS encryption requirements and GDPR privacy rights.

Anahtar Kavram

Data Privacy and Compliance Regulations (PCI-DSS and GDPR Operational Controls)
Soru 1955Soru

A technician is preparing to perform a memory upgrade on a mobile workstation laptop to improve multi-tasking performance for software development. The system currently has one factory-installed memory module and one empty expansion slot. Which TWO of the following hardware considerations must the technician verify to ensure physical compatibility and optimal multi-channel memory performance?

Geçerli olan tümünü seçin

Cevabı ve açıklamayı göster

Cevap: Select SO-DIMM modules specifically designed for smaller mobile form-factor slots.; Install matching memory modules into designated color-coded or alternating slots corresponding to separate memory channels.

Cevap

The technician must select SO-DIMM modules to match the physical laptop form factor and install matching modules across distinct designated memory channels to enable multi-channel performance.
Mobile systems require SO-DIMM form-factor modules due to physical space constraints within the laptop chassis. Additionally, to take advantage of multi-channel architecture (such as dual-channel mode), modules of matching specifications must be installed in slots assigned to separate memory channels.

Adım Adım Çözüm

1
Identify the physical form factor required by the system chassis.
Laptops use SO-DIMM (Small Outline Dual In-line Memory Module) form factors, whereas desktop computers use full-sized DIMMs.
Full-sized DIMMs cannot physically fit into laptop memory slots.
2
Determine the proper slot population scheme for multi-channel memory performance.
Modules must be placed into slots designated for Channel A and Channel B (often alternating slots or specific pairing configurations as detailed in motherboard specs).
Installing modules on separate channels allows the memory controller to access both modules simultaneously, maximizing memory throughput.

Anahtar Kavram

RAM Form Factors and Dual-Channel Slot Population Rules
Soru 1956Soru

Which operational specification or edition constraint correctly corresponds to each remote access technology listed on the left?

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

RDP (Remote Desktop Protocol)
SSH (Secure Shell)
MSRA (Microsoft Remote Assistance)
Telnet

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

Remote Desktop Protocol (RDP) pairs with TCP port 3389 and Windows Pro/Enterprise hosting requirements. Secure Shell (SSH) pairs with TCP port 22 for encrypted CLI access. Microsoft Remote Assistance (MSRA) pairs with invitation-based session screen sharing. Telnet pairs with unencrypted plain text traffic over TCP port 23.
Each remote access tool matches its standard CompTIA A+ specification: Remote Desktop Protocol uses TCP port 3389 and requires Windows Pro or higher to host sessions; Secure Shell uses TCP port 22 for encrypted CLI management; Microsoft Remote Assistance uses invitation-based screen sharing for collaborative user support; Telnet uses TCP port 23 and transmits data in unencrypted cleartext.

Adım Adım Çözüm

1
Determine the network port and Windows edition requirement for Remote Desktop Protocol.
RDP listens on TCP port 3389 and can only host incoming connections on Windows Pro, Enterprise, or Education editions.
Windows Home edition lacks the inbound RDP host feature, though it can initiate connections to external RDP servers.
2
Identify the secure encrypted command-line remote access protocol.
SSH operates over TCP port 22 and encrypts all session data and credentials.
SSH is the standard replacement for legacy unencrypted terminal protocols when managing network equipment and remote servers.
3
Identify the tool designed for collaborative session assistance.
MSRA relies on session invitations to allow simultaneous viewing and shared control of a logged-in user's desktop.
MSRA allows the end user and technician to interact on the same desktop session, unlike RDP which locks the local desktop when a new session starts.
4
Identify the legacy unencrypted terminal protocol.
Telnet uses TCP port 23 and transmits data in unencrypted plain text.
Because Telnet does not encrypt passwords or commands, packet sniffers can intercept sensitive management traffic.

Anahtar Kavram

Remote Access Technologies and Specifications
Soru 1957Soru

A system technician builds a compact workstation using a motherboard equipped with two M.2 storage slots. Slot 1 is connected directly to the CPU and supports NVMe PCIe SSDs. Slot 2 is routed through the chipset and is specified as supporting M.2 SATA drives only. The technician installs a new M.2 NVMe PCIe 4.0 drive into Slot 2. Upon powering on the system and entering the UEFI/BIOS setup, the newly installed SSD is not recognized. Which of the following is the most likely cause of this detection failure?

Cevabı ve açıklamayı göster

Cevap: The M.2 slot is wired strictly for the SATA protocol, preventing an NVMe PCIe drive from communicating with the host controller.

Cevap

The M.2 slot is wired strictly for the SATA protocol, preventing an NVMe PCIe drive from communicating with the host controller.
Although M.2 SSDs share a common form factor, individual M.2 slots on a motherboard may support SATA signaling, PCIe signaling, or both. Inserting a PCIe NVMe drive into an M.2 slot that supports only the SATA protocol prevents the system from establishing a communication link, rendering the SSD unrecognized in the system setup.

Adım Adım Çözüm

1
Analyze the physical and protocol specifications of the motherboard slot.
Slot 2 supports M.2 SATA protocol only.
The host interface dictates which communication protocol (SATA vs PCIe/NVMe) can be used by installed storage devices.
2
Compare the installed drive's protocol requirement with the slot's capability.
An NVMe PCIe SSD relies on PCIe lanes, whereas the slot only provides SATA signaling lines.
If an NVMe drive is placed into a SATA-only slot, the controller cannot establish a PCIe link, causing the drive to remain undetectable in UEFI/BIOS.

Anahtar Kavram

M.2 Interface and Protocol Compatibility (NVMe PCIe vs SATA)
Soru 1958Soru

An IT technician is reviewing system administrative scripts used for environment management across Windows and Linux platforms. Match each script code snippet to the specific language construct or behavior it exhibits.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

for /f "tokens=1-2" %%a in (C:\logs\audit.txt) do ( echo %%a %%b )
Get-ChildItem -Path C:\Logs | Where-Object { $_.LastWriteTime -lt (Get-Date).AddDays(-30) }
Set objFSO = CreateObject("Scripting.FileSystemObject")
if [ -d "/var/log/backup" ]; then echo "Directory exists"; fi

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

1. 'for /f "tokens=1-2" %%a in (...)' matches 'Windows Batch iteration construct parsing structured file tokens natively in cmd.exe'.
2. 'Get-ChildItem -Path ... | Where-Object { $_.LastWriteTime ... }' matches 'PowerShell pipeline construct passing object properties to perform conditionally filtered operations'.
3. 'Set objFSO = CreateObject("Scripting.FileSystemObject")' matches 'VBScript COM object instantiation construct using Windows Script Host (WSH)'.
4. 'if [ -d "/var/log/backup" ]; then echo "Directory exists"; fi' matches 'Bash shell conditional evaluation construct testing directory existence in POSIX environments'.
Each snippet represents a distinct script language's syntax: Batch uses 'for /f' for file parsing, PowerShell uses cmdlets with pipeline object parameters ('$_.'), VBScript uses 'CreateObject' to instantiate COM interfaces under WSH, and Bash uses square bracket conditional tests ('[ -d ... ]') closed with 'fi'.

Adım Adım Çözüm

1
Analyze the syntax and constructs present in each script snippet.
Identified Batch token parsing ('for /f'), PowerShell pipeline object filtering ('Get-ChildItem | Where-Object'), VBScript COM creation ('CreateObject'), and Bash file test conditionals ('if [ -d ... ]').
Different administrative scripting environments rely on distinct construct syntax and runtime engines.
2
Map each snippet to its corresponding environment and execution behavior.
Paired each code construct with its matching functional definition.
Accurate identification of language-specific constructs ensures proper script maintenance and cross-platform automation.

Anahtar Kavram

Identification of scripting language constructs, execution environments, and basic control flows across Windows Batch, PowerShell, VBScript, and Bash.
Soru 1959Soru

While performing routine maintenance on a system administrator's workstation, a technician notices an unauthorized interactive remote shell executing administrative scripts in real time. The workstation contains volatile memory data critical for the incident investigation. Which action should the technician take FIRST to contain the threat while preserving digital evidence integrity?

Cevabı ve açıklamayı göster

Cevap: Disconnect the network interfaces to isolate the workstation while leaving the system powered on.

Cevap

Disconnect the network interfaces to isolate the workstation while leaving the system powered on.
Isolating network interfaces (such as unplugging the Ethernet cable or disabling Wi-Fi) immediately halts remote command execution and data exfiltration without losing RAM contents. Keeping the system powered on preserves volatile forensic artifacts required for forensic imaging and memory analysis.

Adım Adım Çözüm

1
Identify the active threat and assess the evidence state.
The workstation is undergoing an active remote attack, and volatile RAM holds vital forensic evidence.
Understanding the order of volatility dictates that live RAM data will be lost if the machine is powered off.
2
Isolate the compromised system from all network connections.
Network communication is terminated, stopping the remote attacker's access and preventing lateral spread across the network.
Network isolation contains the security incident immediately without altering or erasing volatile RAM evidence.
3
Escalate the incident to the designated Incident Response / Security Operations team.
Proper authorities take ownership of evidence collection and chain of custody documentation.
First responders must follow official reporting escalation policies once containment is established.

Anahtar Kavram

First Responder Incident Containment and Order of Volatility
Soru 1960Soru

A system builder is selecting a power supply unit (PSU) for a custom workstation. The planned hardware components have the following continuous power demands:

- Central Processing Unit (CPU): 105 W105\text{ W}
- Dedicated Graphics Card (GPU): 250 W250\text{ W}
- Solid-State Drives and Cooling Fans: 45 W45\text{ W}
- Sound Capture Expansion Card: 20 W20\text{ W}

To prevent power throttling and allow for system longevity, the technician specifies that the total power consumption under full load must not exceed 80%80\% of the power supply's total rated wattage rating (providing a 20%20\% safety capacity margin). Which of the following is the minimum PSU wattage rating required for this system?

Cevabı ve açıklamayı göster

Cevap: 525 W525\text{ W}

Cevap

The minimum recommended power supply unit rating is 525 W525\text{ W}.
The total continuous power draw of all components is 105 W+250 W+45 W+20 W=420 W105\text{ W} + 250\text{ W} + 45\text{ W} + 20\text{ W} = 420\text{ W}. To ensure this total load does not exceed 80%80\% of the power supply's continuous capacity rating, divide 420 W420\text{ W} by 0.800.80, which equals 525 W525\text{ W}.

Adım Adım Çözüm

1
Calculate total continuous component power draw
105 W+250 W+45 W+20 W=420 W105\text{ W} + 250\text{ W} + 45\text{ W} + 20\text{ W} = 420\text{ W}
Sum all individual hardware power requirements across CPU, GPU, drives/fans, and expansion cards.
2
Apply the 80% maximum target load constraint
420 W0.80=525 W\frac{420\text{ W}}{0.80} = 525\text{ W}
Dividing total power draw by 0.80 establishes the minimum rated PSU wattage needed so that 420 W represents exactly 80% of total capacity.

Anahtar Kavram

Power supply unit (PSU) wattage calculation and safety headroom planning
ÖncekiSayfa 98 / 178Sonraki