Tüm alıştırma soruları
1809 soru
An IT technician is replacing the thermal solution on a desktop computer that has been experiencing automatic shutdowns caused by CPU overheating. After unmounting the original heat sink, the technician notices hardened, degraded thermal compound on the processor's heat spreader. Which of the following describes the correct procedure the technician should follow before mounting the replacement cooling unit?
A technician is assembling a workstation inside a microATX desktop chassis that provides exactly four rear expansion slot cutouts. The system requirements call for installing three separate expansion cards: a dual-slot PCIe x16 graphics card, a single-slot PCIe x4 RAID controller card, and a single-slot PCIe x1 sound card. Which of the following motherboard form factor and expansion slot layout choices MUST the technician select to ensure all three cards fit into the chassis?
A field technician is troubleshooting a high-end laptop brought in for repair. The user reports that while system power indicators turn on and external displays render video properly, the built-in OLED screen remains completely dark. The technician attributes the failure to a blown display inverter board and orders a replacement. Which of the following is the most accurate assessment of the technician's troubleshooting plan?
A small accounting firm recently purchased five off-the-shelf desktop computers running Windows 11 Home for its new staff members. The IT consultant needs to join these workstations to the firm's existing Active Directory domain and configure centralized security policies using Group Policy. When attempting to complete the setup, the consultant realizes the domain join option is unavailable. Which of the following explains why the consultant cannot complete this task?
A field technician is deploying mobile workstation laptops for a group of engineers who require dual external 4K video output. The technician connects a multi-port docking station to the laptop's built-in USB Type-C port, but neither external monitor receives a video signal, even though USB peripherals connected to the dock function normally. The technician assumed that the physical USB Type-C port would support DisplayPort Alternate Mode and Thunderbolt high-speed video transmission. Which of the following best explains the root cause of this issue?
An IT technician is resolving an issue on a critical engineering workstation that experiences system instability during CAD rendering. The technician interviewed the user, reviewed system event logs, and suspected a newly installed graphics driver update was causing memory allocation faults. In a controlled test environment, the technician successfully verified this hypothesis by rolling back the driver to a previous stable version, which completely eliminated the instability. According to the CompTIA troubleshooting methodology, which of the following actions should the technician perform NEXT?
A field technician is troubleshooting hardware and cellular connectivity issues on corporate mobile devices. A smartphone recently had its motherboard replaced due to physical damage. Although the original SIM card was reinserted, the device fails to connect to the cellular network and displays an authorization error. The cellular carrier requires registering the 15-digit unique hardware identifier assigned to the new cellular transceiver radio built into the replacement motherboard. To resolve the cellular registration failure on this repaired device, which of the following is the correct action for the technician to take?
A systems technician is troubleshooting network access issues on a newly provisioned workstation connected to an enterprise wired network outlet. The workstation interface receives an IP address of with a subnet mask of . The switch port link indicator shows a solid green status. When the technician configures a static IP address of with default gateway , ICMP pings to the default gateway succeed, but attempts to access external websites by domain name fail, and subsequent dynamic requests time out. Which of the following is the MOST likely cause of these symptoms?
A desktop workstation hosting a local database experiences severe performance degradation and intermittent file read errors. Upon checking the storage management console, the technician notes that the two-disk hardware RAID 1 array is marked as Degraded, with Disk 1 reporting multiple uncorrectable S.M.A.R.T. read sector errors. The surviving drive, Disk 0, is reported as healthy and online. Which of the following is the most appropriate immediate action for the technician to take to restore full array redundancy?
A network administrator is troubleshooting an enterprise database server utilizing a hardware RAID 10 array composed of four NVMe solid-state drives. During peak transaction periods, the server logs file system write timeouts, yet the hardware RAID controller reports the overall volume status as 'Optimal' and all individual member disks as 'Online'. Drive health telemetry reveals that one specific SSD in Span 0 is experiencing severe thermal throttling and logging a high count of uncorrectable S.M.A.R.T. media errors. Which of the following is the most appropriate action to take to address this issue while protecting system availability and data integrity?
An IT technician is troubleshooting a newly installed network drop in an industrial facility. A workstation connected to a Gigabit Ethernet switch experiences severe packet loss and fails to reach expected throughput. Testing the cable run with a wiremap tester reveals that the wall outlet end is wired to the T568B standard, while the patch panel end is wired to the T568A standard. The switch port LED displays a solid link at 100 Mbps, but the switch port log reports excessive Frame Check Sequence (FCS) errors and late collisions during transmission. Which of the following best describes the root cause of this issue and the appropriate corrective action?
A technician is troubleshooting intermittent wireless connectivity issues for laptops in a high-density office area. The laptops experience high packet loss and severe throughput degradation despite showing full signal strength for the corporate SSID. A wireless spectrum analysis reveals that three neighboring access points covering this workspace are configured to broadcast on 2.4 GHz channels 1, 3, and 5. Which of the following is the MOST likely cause of the network instability?
A desktop support technician updates a domain Group Policy setting for a user. To ensure the updated policy settings take effect immediately on the user's local Windows workstation without restarting the computer or waiting for the default background refresh interval, which command should the technician execute?
A tier-2 support specialist is investigating an issue where an enterprise workstation lost access to a shared network directory immediately following a scheduled operating system update. The specialist interviewed the user, reviewed system log files, and confirmed the workstation has a valid static IP address on the local subnet. Based on these findings, the specialist suspects that the update modified local firewall rules to block inbound file sharing protocols. According to the standard CompTIA 6-step troubleshooting methodology, which of the following actions should the specialist take NEXT?
A company needs to prevent unauthorized individuals from following authorized employees into a highly secure server room, a practice known as tailgating. Which of the following physical security controls is specifically designed to enforce single-person entry at an access point?
A technician servicing a Windows workstation needs to initiate an immediate restart of the computer using the Command Prompt. Which of the following commands should the technician execute?
A graphic designer reports that saving large project files on their workstation has become noticeably slow. Upon opening the storage controller utility, a technician observes that one of the two SATA SSDs in a hardware RAID 1 array is displaying a high count of S.M.A.R.T. read errors, though the array status remains active. Which of the following is the most appropriate initial action to prevent data loss and safely restore array performance?
A systems administrator is configuring an automated network deployment of Windows 11 Pro across a fleet of custom workstations equipped with a new hardware RAID storage controller. The administrator creates a deployment share and configures an `autounattend.xml` answer file. However, when Windows Setup launches on the target clients via PXE, the installation halts at the disk partition selection phase with the error message: "We couldn't find any drives. To get a storage driver, click Load driver." Reviewing the `autounattend.xml` file reveals that the custom RAID controller driver package was placed in the `offlineServicing` configuration pass. Which of the following actions should the administrator take to resolve this issue while maintaining an automated deployment process?
An IT technician is servicing a system after replacing the CPU cooler and modular power supply. When the power button is pressed, the power supply unit (PSU) makes a distinct clicking sound, the cooling fans turn for a fraction of a second, and the computer instantly powers down. Pressing the power button again has no effect until the AC power cable is unplugged and reattached. The technician confirms that total system power requirements are well within the PSU's rated continuous output. Which of the following is the most likely cause of this symptom?
A video editor reports severe performance degradation and occasional read timeouts when accessing archived media projects on a workstation. System diagnostics reveal that the workstation utilizes a software RAID 0 volume for scratch cache and a hardware RAID 10 array for long-term project storage. Controller logs show that a single disk in the hardware RAID 10 array has suffered a total mechanical failure and is offline, while all other physical drives report healthy status. Which of the following is the most appropriate immediate action for the technician to take to restore fault tolerance to the storage system?