Oscilloscopes

9 soru

Soru 1Soru →

Match each oscilloscope front-panel control or display feature on the left with its corresponding measurement function on the right.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

Volts/Div control
Time/Div control
Trigger control
Graticule grid

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

Volts/Div matches vertical scale (amplitude/voltage measurement), Time/Div matches horizontal sweep rate (period/frequency measurement), Trigger matches waveform stabilization, and Graticule grid matches the calibrated measurement overlay.
Each oscilloscope feature is mapped directly to its core operational role: the Volts/Div knob scales the vertical axis for voltage amplitude, Time/Div scales the horizontal axis for time intervals, the Trigger synchronizes the horizontal sweep for a stable trace, and the Graticule acts as the calibrated grid overlay.

Adım Adım Çözüm

1
Identify the vertical axis control and its function
Volts/Div controls vertical scaling to measure voltage values such as peak or peak-to-peak amplitude.
Vertical displacement on an oscilloscope screen is directly proportional to signal voltage.
2
Identify the horizontal axis control and its function
Time/Div controls horizontal sweep time to measure period and calculate frequency (f=1Tf = \frac{1}{T}).
Horizontal displacement represents elapsed time across the screen.
3
Identify the synchronization mechanism
The Trigger control stabilizes the signal display.
Without proper triggering, the trace starts at random points of the cycle, causing the waveform to scroll continuously.
4
Identify the physical reference markings
The Graticule grid provides the reference divisions for counting units.
The graticule lines allow the operator to multiply division counts by the scale settings.

Anahtar Kavram

Basic oscilloscope controls and display anatomy
Tahmini Süre:45s
Soru 2Soru →

An electronics technician connects an oscilloscope to test an alternating current circuit. The vertical scale (Volts/Div) is set to 5 V/div5\text{ V/div}, and the displayed waveform has a total vertical span of 4 divisions4\text{ divisions} from the highest peak to the lowest trough. What is the peak-to-peak voltage (Vp-pV_{\text{p-p}}) of the signal?

Cevabı ve açıklamayı göster

Cevap: 20 V20\text{ V}

Cevap

20 V20\text{ V}
Peak-to-peak voltage (Vp-pV_{\text{p-p}}) is the total voltage difference between the highest positive peak and the lowest negative trough of a waveform. Multiplying the total vertical displacement of 4 divisions4\text{ divisions} by the vertical sensitivity setting of 5 V/div5\text{ V/div} gives 4×5=20 V4 \times 5 = 20\text{ V}.

Adım Adım Çözüm

1
Identify the given vertical division count and the Volts/Div scale setting.
Vertical span = 4 divisions4\text{ divisions}; Vertical scale = 5 V/div5\text{ V/div}.
The vertical axis on an oscilloscope measures voltage according to the specified Volts/Div sensitivity.
2
Calculate the peak-to-peak voltage (Vp-pV_{\text{p-p}}) by multiplying the total vertical divisions by the Volts/Div setting.
Vp-p=4 divisions×5 V/div=20 VV_{\text{p-p}} = 4\text{ divisions} \times 5\text{ V/div} = 20\text{ V}.
Each vertical grid square represents 5 V5\text{ V}, so 44 full squares equal 20 V20\text{ V} from minimum trough to maximum peak.

Anahtar Kavram

Calculating peak-to-peak voltage on an oscilloscope using graticule divisions and the Volts/Div scale setting
Tahmini Süre:45s
Soru 3Soru →

An oscilloscope displays a periodic alternating voltage waveform on its screen. One complete cycle of the waveform occupies 4 horizontal divisions4\text{ horizontal divisions} across the graticule. If the oscilloscope's horizontal time base (Time/Div) control is set to 15 ms/div15\text{ ms/div}, what is the period of the waveform in milliseconds?

Cevabı ve açıklamayı göster

Cevap: 60

Cevap

60 ms60\text{ ms}
The period (TT) of a signal displayed on an oscilloscope is found by multiplying the number of horizontal divisions for one complete cycle by the Time/Div control setting: 4 divisions×15 ms/div=60 ms4\text{ divisions} \times 15\text{ ms/div} = 60\text{ ms}.

Adım Adım Çözüm

1
Identify the number of horizontal graticule divisions occupied by one full waveform cycle.
4 divisions4\text{ divisions}
On an oscilloscope display, the horizontal axis represents time, and one full cycle corresponds to the period (TT).
2
Multiply the division count by the horizontal scale factor (15 ms/div15\text{ ms/div}).
4 div×15 ms/div=60 ms4\text{ div} \times 15\text{ ms/div} = 60\text{ ms}
Multiplying the span in divisions by the time allocated per division gives the total duration of one cycle.

Anahtar Kavram

Calculating waveform period from oscilloscope horizontal division settings
Tahmini Süre:45s
Soru 4Soru →

An electronics technician is troubleshooting an intermittent circuit fault using an analog/digital oscilloscope. Match each oscilloscope control feature on the left with its correct functional operation on the right.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

Trigger Level
AC Coupling
Timebase (SEC/DIV)
Vertical Position

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

Trigger Level matches setting the voltage threshold to stabilize the sweep; AC Coupling matches inserting a series capacitor to block DC bias; Timebase (SEC/DIV) matches controlling horizontal sweep speed per division; Vertical Position matches shifting the trace vertically without changing signal amplitude.
Each control corresponds directly to its front-panel function: Trigger Level establishes the voltage threshold for horizontal sweep synchronization; AC Coupling blocks DC bias using an internal capacitor to view small AC variations; Timebase dictates horizontal sweep speed per division; and Vertical Position shifts the trace vertically for convenient graticule alignment.

Adım Adım Çözüm

1
Identify the synchronization function of the oscilloscope.
Trigger Level sets the precise voltage threshold required to synchronize the horizontal sweep generator with the incoming signal.
Without proper trigger settings, periodic waveforms scroll or overlap asynchronously on the screen.
2
Identify the input filtering configuration.
AC Coupling engages an internal series capacitor to block steady DC levels while passing time-varying AC signals.
This allows small AC fluctuations (such as power supply ripple) to be viewed at high vertical sensitivity without driving the trace off-screen.
3
Identify the horizontal time-domain scaling control.
Timebase (SEC/DIV) calibrates the horizontal rate of trace movement across graticule divisions.
Adjusting SEC/DIV allows the user to expand or compress the horizontal waveform display to measure period and frequency.
4
Identify the trace alignment control.
Vertical Position relocates the waveform baseline up or down across the vertical graticule.
This provides visual alignment against graticule reference lines without modifying vertical gain (Volts/Div).

Anahtar Kavram

Oscilloscope Front-Panel Controls and Signal Conditioning
Tahmini Süre:1m 15s
Soru 5Soru →

An audio technician connects an oscilloscope to analyze a recurring tone from a signal generator. The horizontal Time/Div control is set to 250 μs/div250\text{ }\mu\text{s/div}. On the graticule display, exactly two complete cycles of the sine wave span 8 horizontal divisions8\text{ horizontal divisions}. What is the frequency of the audio signal?

Cevabı ve açıklamayı göster

Cevap: 1 kHz1\text{ kHz}

Cevap

The frequency of the audio signal is 1 kHz1\text{ kHz} (1000 Hz1{}000\text{ Hz}).
One complete sine wave cycle occupies 8 divisions2=4 divisions\frac{8\text{ divisions}}{2} = 4\text{ divisions}. Multiplying by the horizontal timebase of 250 μs/div250\text{ }\mu\text{s/div} gives a period of T=1000 μs=1 ms=0.001 sT = 1{}000\text{ }\mu\text{s} = 1\text{ ms} = 0.001\text{ s}. The frequency is f=1T=10.001 s=1000 Hz=1 kHzf = \frac{1}{T} = \frac{1}{0.001\text{ s}} = 1{}000\text{ Hz} = 1\text{ kHz}.

Adım Adım Çözüm

1
Determine the number of horizontal divisions occupied by one complete cycle.
Divisions per cycle=8 divisions2 cycles=4 div/cycle\text{Divisions per cycle} = \frac{8\text{ divisions}}{2\text{ cycles}} = 4\text{ div/cycle}
The period of a periodic wave is defined by the horizontal duration of one full cycle.
2
Calculate the period (TT) of the waveform by multiplying divisions per cycle by the horizontal timebase scale.
T=4 div×250 μs/div=1000 μs=1×10−3 sT = 4\text{ div} \times 250\text{ }\mu\text{s/div} = 1000\text{ }\mu\text{s} = 1 \times 10^{-3}\text{ s}
The Time/Div control establishes the time value represented by each graticule division.
3
Calculate the frequency (ff) using the reciprocal formula f=1Tf = \frac{1}{T}.
f=11×10−3 s=1000 Hz=1 kHzf = \frac{1}{1 \times 10^{-3}\text{ s}} = 1000\text{ Hz} = 1\text{ kHz}
Frequency is the inverse of the period in seconds.

Anahtar Kavram

Calculating waveform period and frequency from oscilloscope horizontal timebase settings and graticule divisions.
Tahmini Süre:1m 0s
Soru 6Soru →

A radio technician is testing the output of an RF signal generator using an oscilloscope. The horizontal timebase control is set to 250 μs/div250\text{ }\mu\text{s/div}. On the screen graticule, a continuous sinusoidal waveform is observed where exactly 2.5 complete cycles2.5\text{ complete cycles} span across 8 horizontal divisions8\text{ horizontal divisions}. What is the frequency of this signal, in hertz (Hz\text{Hz})?

Cevabı ve açıklamayı göster

Cevap: 1250

Cevap

1250 Hz
The total duration of the 8 horizontal divisions8\text{ horizontal divisions} at 250 μs/div250\text{ }\mu\text{s/div} is 2000 μs2000\text{ }\mu\text{s} (2 ms2\text{ ms}). Dividing by the 2.5 complete cycles2.5\text{ complete cycles} gives a period of T=800 μs=0.0008 sT = 800\text{ }\mu\text{s} = 0.0008\text{ s} per cycle. Taking the reciprocal gives the frequency: f=1/0.0008 s=1250 Hzf = 1 / 0.0008\text{ s} = 1250\text{ Hz}.

Adım Adım Çözüm

1
Calculate the total elapsed time across the observed graticule divisions.
Total time =8 div×250 μs/div=2000 μs= 8\text{ div} \times 250\text{ }\mu\text{s/div} = 2000\text{ }\mu\text{s}
The horizontal axis represents time, and the timebase setting indicates the duration per division.
2
Calculate the period (TT) of a single cycle.
T=2000 μs2.5 cycles=800 μs=800×10−6 s=0.0008 sT = \frac{2000\text{ }\mu\text{s}}{2.5\text{ cycles}} = 800\text{ }\mu\text{s} = 800 \times 10^{-6}\text{ s} = 0.0008\text{ s}
The period is the time required to complete one single cycle.
3
Calculate the frequency (ff) from the period.
f=1T=10.0008 s=1250 Hzf = \frac{1}{T} = \frac{1}{0.0008\text{ s}} = 1250\text{ Hz}
Frequency in hertz is the reciprocal of the period in seconds (f=1/Tf = 1/T).

Anahtar Kavram

Calculating waveform period and frequency from oscilloscope horizontal timebase settings and graticule divisions.
Tahmini Süre:1m 30s
Soru 7Soru →

An oscilloscope is used to measure an alternating signal. The horizontal sweep rate (Time/Div) is set to 8 μs/div8\text{ }\mu\text{s/div}, and one complete cycle of the waveform spans exactly 5 horizontal divisions5\text{ horizontal divisions} across the graticule. What is the frequency of this signal in kilohertz (kHz\text{kHz})?

Cevabı ve açıklamayı göster

Cevap: 25

Cevap

The frequency of the signal is 25 kHz25\text{ kHz}.
One full waveform cycle occupies 55 horizontal divisions at 8 μs/division8\text{ }\mu\text{s/division}, giving a period of T=40 μsT = 40\text{ }\mu\text{s} (40×10−6 s40 \times 10^{-6}\text{ s}). The frequency is the reciprocal of the period (f=1T=140×10−6 s=25000 Hzf = \frac{1}{T} = \frac{1}{40 \times 10^{-6}\text{ s}} = 25{}000\text{ Hz}), which equals 25 kHz25\text{ kHz}.

Adım Adım Çözüm

1
Multiply the number of horizontal graticule divisions per cycle by the time base setting to find the period (TT).
T=5 divisions×8 μs/div=40 μs=40×10−6 sT = 5\text{ divisions} \times 8\text{ }\mu\text{s/div} = 40\text{ }\mu\text{s} = 40 \times 10^{-6}\text{ s}
Horizontal divisions represent the time dimension on an oscilloscope display.
2
Calculate the frequency (ff) in hertz using the reciprocal relationship f=1Tf = \frac{1}{T}.
f=140×10−6 s=25000 Hzf = \frac{1}{40 \times 10^{-6}\text{ s}} = 25{}000\text{ Hz}
Frequency is defined as the number of cycles per second.
3
Convert the resulting frequency from hertz (Hz\text{Hz}) to kilohertz (kHz\text{kHz}).
25000 Hz1000=25 kHz\frac{25{}000\text{ Hz}}{1{}000} = 25\text{ kHz}
The question specifies the final answer unit as kilohertz.

Anahtar Kavram

Calculating waveform period and frequency from oscilloscope horizontal Time/Div settings and graticule division counts
Tahmini Süre:1m 0s
Soru 8Soru →

A communications technician connects an oscilloscope to monitor an unmodulated carrier signal from a transmitter stage. A standard 10×10\times passive attenuation probe is connected to Channel 1, while the oscilloscope input channel remains set to standard 1×1\times scale. On the display, the sinusoidal trace spans 6 vertical divisions6\text{ vertical divisions} from peak to peak with the vertical sensitivity set to 2 V/div2\text{ V/div}. Horizontally, exactly 4 complete cycles4\text{ complete cycles} span across 8 divisions8\text{ divisions} with the horizontal timebase set to 5 μs/div5\text{ }\mu\text{s/div}. What are the true peak-to-peak voltage (Vp-pV_{\text{p-p}}) and frequency (ff) of the input signal?

Cevabı ve açıklamayı göster

Cevap: 120 Vp-p and 100 kHz120\text{ V}_{\text{p-p}}\text{ and }100\text{ kHz}

Cevap

120 Vp-p and 100 kHz120\text{ V}_{\text{p-p}}\text{ and }100\text{ kHz}
The true peak-to-peak voltage is calculated by multiplying the 6 vertical divisions6\text{ vertical divisions} by 2 V/div2\text{ V/div} and accounting for the 10×10\times probe factor, yielding 120 Vp-p120\text{ V}_{\text{p-p}}. The period for one cycle is 2 divisions×5 μs/div=10 μs2\text{ divisions} \times 5\text{ }\mu\text{s/div} = 10\text{ }\mu\text{s}, which gives a frequency of f=1/(10 μs)=100 kHzf = 1 / (10\text{ }\mu\text{s}) = 100\text{ kHz}.

Adım Adım Çözüm

1
Calculate the displayed peak-to-peak voltage from the vertical graticule divisions and Volts/Div setting
Vp-p(displayed)=6 divisions×2 V/div=12 VV_{\text{p-p(displayed)}} = 6\text{ divisions} \times 2\text{ V/div} = 12\text{ V}
Each vertical division represents 2 volts on the scope screen.
2
Apply the 10X attenuation probe multiplier to obtain the true input voltage
Vp-p(true)=12 V×10=120 Vp-pV_{\text{p-p(true)}} = 12\text{ V} \times 10 = 120\text{ V}_{\text{p-p}}
A 10X attenuation probe divides the circuit voltage by 10 before reaching the scope input, so the observed display value must be multiplied by 10 when the scope is not set to auto-scale.
3
Determine the horizontal division span for one complete cycle
Divisions per cycle=8 divisions4 cycles=2 div/cycle\text{Divisions per cycle} = \frac{8\text{ divisions}}{4\text{ cycles}} = 2\text{ div/cycle}
One full period corresponds to exactly one complete waveform cycle.
4
Calculate the period (T) of the waveform using the horizontal timebase setting
T=2 div×5 μs/div=10 μs=10×10−6 sT = 2\text{ div} \times 5\text{ }\mu\text{s/div} = 10\text{ }\mu\text{s} = 10 \times 10^{-6}\text{ s}
Multiplying the division width of one cycle by the timebase gives the duration of one period.
5
Calculate the frequency (f) using the reciprocal of the period
f=1T=110×10−6 s=100000 Hz=100 kHzf = \frac{1}{T} = \frac{1}{10 \times 10^{-6}\text{ s}} = 100{}000\text{ Hz} = 100\text{ kHz}
Frequency is the inverse of the period: f=1/Tf = 1/T.

Anahtar Kavram

Oscilloscope graticule measurement incorporating 10X probe scaling and period-to-frequency conversion
Tahmini Süre:2m 0s
Soru 9Soru →

A technician is evaluating an AC ripple voltage on a DC power supply using an oscilloscope. The vertical sensitivity control (Volts/Div) is set to 50 mV/div50\text{ mV/div}. If the displayed waveform occupies a total of 6 vertical divisions6\text{ vertical divisions} from its lowest trough to its highest crest, what is the peak voltage (VpkV_{\text{pk}}) of the ripple?

Cevabı ve açıklamayı göster

Cevap: 150 mV150\text{ mV}

Cevap

The peak voltage of the ripple is 150 mV150\text{ mV}.
Multiplying the total vertical deflection (6 divisions6\text{ divisions}) by the vertical sensitivity (50 mV/div50\text{ mV/div}) yields a peak-to-peak voltage of 300 mV300\text{ mV}. Peak voltage (VpkV_{\text{pk}}) measures the amplitude from the reference centerline to the positive crest, which equals half of the peak-to-peak voltage: 300 mV2=150 mV\frac{300\text{ mV}}{2} = 150\text{ mV}.

Adım Adım Çözüm

1
Calculate the peak-to-peak voltage (Vp-pV_{\text{p-p}})
Vp-p=6 divisions×50 mV/div=300 mVV_{\text{p-p}} = 6\text{ divisions} \times 50\text{ mV/div} = 300\text{ mV}
The total vertical span from crest to trough represents the full peak-to-peak voltage.
2
Calculate the peak voltage (VpkV_{\text{pk}})
Vpk=Vp-p2=300 mV2=150 mVV_{\text{pk}} = \frac{V_{\text{p-p}}}{2} = \frac{300\text{ mV}}{2} = 150\text{ mV}
Peak voltage is the amplitude measured from the center baseline to either peak, which is half of the peak-to-peak value.

Anahtar Kavram

Determining peak voltage from peak-to-peak vertical graticule measurements on an oscilloscope.
Tahmini Süre:1m 0s