Tüm alıştırma soruları

5215 soru

Soru 1021Soru →

A 5-character security passcode must be created using the digits 0 through 9. The passcode must begin with an odd digit, end with an even digit, and no digit may be repeated anywhere in the passcode. How many different passcodes can be created?

Cevabı ve açıklamayı göster

Cevap: 8,400

Cevap

8,400
To find the total number of possible passcodes, we evaluate the restricted positions first. The first digit must be odd (5 options: 1, 3, 5, 7, 9). The last digit must be even (5 options: 0, 2, 4, 6, 8). Because odd and even sets do not overlap, exactly one odd and one even digit are removed from the total pool of 10 digits. Because repetition is not allowed, 10−2=810 - 2 = 8 digits remain available for the middle three positions. The number of ways to fill the middle three spots is a permutation without repetition: 8×7×6=3368 \times 7 \times 6 = 336. Multiplying the independent choices for all positions gives 5×336×5=8,4005 \times 336 \times 5 = 8,400.

Adım Adım Çözüm

1
Determine the number of options for the first character.
5 options
The first digit must be odd, and there are 5 odd digits (1, 3, 5, 7, 9) in the standard set of digits from 0-9.
2
Determine the number of options for the last character.
5 options
The last digit must be even, and there are 5 even digits (0, 2, 4, 6, 8) in the standard set.
3
Determine the number of available digits for the remaining three middle positions.
8 digits
There are 10 digits in total. Since no digit may be repeated and 2 distinct digits have already been used for the first and last positions, exactly 8 digits remain available.
4
Calculate the number of ways to arrange the middle three characters.
336 ways
Using permutations for the 3 middle spots from the 8 remaining digits: 8 × 7 × 6 = 336.
5
Calculate the total number of possible passcodes.
8,400 passcodes
Using the Fundamental Counting Principle, multiply the number of options for each stage: 5 × 336 × 5 = 8,400.

Anahtar Kavram

Fundamental Counting Principle with Restrictions
Soru 1022Soru →

A technician is preparing to install a heat-sensitive transistor onto a printed circuit board terminal using an electric soldering pencil and rosin-core solder. What is the correct sequential order of steps the technician must follow to complete the solder connection properly without damaging the component or creating a defective joint?

Öğeleri doğru sıraya koymak için sürükleyin

Cevabı ve açıklamayı göster

Cevap

The proper sequence is: (1) Clean and tin the soldering iron tip on a damp sponge, (2) attach a thermal shunt to the transistor lead, (3) apply the iron tip simultaneously to both the lead and the pad, (4) feed rosin-core solder into the heated junction opposite the iron, and (5) remove the solder, withdraw the iron, and allow the connection to cool undisturbed.
High-reliability electronic soldering follows a strict thermodynamic and metallurgical order: preparing the heat transfer medium (cleaning/tinning), safeguarding delicate active devices with a thermal shunt, heating the target metals to soldering temperature, feeding flux-cored solder directly into the joint to facilitate capillary action, and finally removing the heat source while avoiding physical disturbance during crystallization.

Adım Adım Çözüm

1
Prepare and tin the soldering tip
The tip is free of oxidized residue and coated with a bright, molten solder film.
Tinning creates a liquid solder bridge that dramatically improves heat conductivity into the connection.
2
Position protective thermal tooling
A metallic heat sink clip is fastened between the transistor body and the soldering zone.
Semiconductor junctions can be permanently damaged by excessive heat; the shunt dissipates thermal energy before reaching internal silicone layers.
3
Preheat the connection elements
Both the copper terminal pad and the component lead reach the wetting temperature of solder.
Solder only adheres properly and flows over surfaces that are at or above its liquidus temperature.
4
Introduce solder alloy and flux to the workpiece
Rosin flux cleans surface oxides while molten solder forms a concave wetting fillet around the lead.
Melting solder onto the workpieces rather than directly against the iron tip prevents flux burnout and cold joints.
5
Remove tools and allow undisturbed solidification
The alloy freezes into a shiny, smooth, mechanically sound metallurgical bond.
Moving the joint while the alloy passes through its plastic phase creates a crystallized, high-resistance cold solder joint.

Anahtar Kavram

Procedural stages of electronic soldering, thermal protection, and joint solidification

Alternatif Yöntem

For desoldering rather than soldering, the sequence reverses slightly: clean/tin tip, apply desoldering braid or vacuum pump nozzle to the preheated joint, depress the suction plunger, and verify lead release before component removal.
Tahmini Süre:1m 30s
Soru 1023Soru →

Which of the following atomic characteristics explains why metals such as copper and silver are classified as good electrical conductors?

Cevabı ve açıklamayı göster

Cevap: They have loosely held valence electrons that move freely from atom to atom.

Cevap

They have loosely held valence electrons that move freely from atom to atom.
Electrical conductors such as copper, silver, and gold have few electrons in their outermost shell that are held loosely by the nucleus. These free electrons move easily from one atom to another when a voltage is applied, permitting electric current to flow with minimal resistance.

Adım Adım Çözüm

1
Analyze the atomic structure of electrical conductors.
Conductors like copper, silver, and aluminum typically have only one or two valence electrons in their outermost shell.
Understanding atomic structure determines how easily charges can move through a material.
2
Determine how these valence electrons behave under an applied electrical potential.
Because these outer electrons are loosely bound to the nucleus, small electromotive forces cause them to drift freely across the lattice as electric current.
This free electron mobility is what defines high electrical conductivity.

Anahtar Kavram

Conductors, Insulators, and Semiconductors
Tahmini Süre:45s
Soru 1024Soru →

In power supply filtering and voltage transformation circuits, inductors and transformers operate through specific electromagnetic principles and structural designs. Match each electromagnetic concept or construction feature with its correct operational description.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

Counter Electromotive Force (Back EMF)
Mutual Inductance
Inductive Reactance (XLX_L)
Laminated Iron Core

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

Counter Electromotive Force matches the generation of an opposing internal voltage; Mutual Inductance matches the transfer of energy between adjacent coils via alternating magnetic flux; Inductive Reactance matches frequency-dependent opposition to alternating current; Laminated Iron Core matches the structural method using insulated steel sheets to minimize eddy current losses.
Each concept correctly identifies a foundational operating mechanism in inductive components: self-induction produces Counter EMF opposing current changes; mutual inductance allows electrical isolation and power transfer across coils; inductive reactance describes frequency-dependent AC opposition; and core lamination mitigates destructive eddy current losses in iron-core devices.

Adım Adım Çözüm

1
Identify the definition of self-induction and Back EMF in single inductors.
Back EMF is the self-induced counter-voltage opposing any change in coil current.
Inductors store energy in a magnetic field; when current fluctuates, the changing field generates an opposing potential difference.
2
Identify the principle of mutual induction linking transformer windings.
Mutual inductance is the electromagnetic coupling where changing magnetic flux from one winding induces voltage in another.
Transformers rely on shared magnetic flux across electrically isolated primary and secondary coils.
3
Identify the dynamic AC behavior of inductors defined by inductive reactance.
Inductive reactance (XLX_L) represents the AC opposition given by XL=2πfLX_L = 2\pi f L.
Reactance is measured in ohms and increases proportionally with both frequency and inductance value.
4
Identify the purpose of laminations in magnetic transformer and inductor cores.
Laminations break up conductive loops to suppress eddy current power losses.
Solid conductive iron cores develop strong circular induced currents (eddy currents) that cause severe heating unless laminated.

Anahtar Kavram

Fundamental electromagnetic properties and structural principles governing inductors and transformers
Tahmini Süre:1m 15s
Soru 1025Soru →

An industrial technician is troubleshooting an unpowered control cabinet and needs to measure the electrical resistance of a 24-volt relay coil to determine if the internal winding is defective. What is the correct chronological sequence of steps the technician should follow to perform this measurement safely and accurately?

Öğeleri doğru sıraya koymak için sürükleyin

Cevabı ve açıklamayı göster

Cevap

The technician must first verify the circuit is de-energized, disconnect at least one coil terminal to isolate it from parallel paths, configure the multimeter into resistance mode with correct lead placement, apply the test probes across the coil terminals, and finally compare the resulting reading against manufacturer specifications.
The correct procedural order begins with personal and equipment safety by de-energizing the circuit, followed by component isolation to eliminate parallel resistance paths. Next, the multimeter is properly configured with leads in COM and V/Ω\Omega ports on the resistance setting. The probes are then placed across the terminals to obtain a reading, and the sequence finishes by comparing the measured value to the manufacturer's technical specifications.

Adım Adım Çözüm

1
Ensure all power to the system is shut down and locked out.
The control circuit is fully de-energized and safe for ohmmeter connection.
Ohmmeter circuits inject their own small reference current; measuring on a live circuit will blow meter fuses or cause severe damage.
2
Disconnect at least one conductor from the relay coil terminals.
The relay coil is electrically isolated from any parallel components.
Parallel circuit paths provide alternative routes for test current, resulting in false, lower-than-actual resistance readings.
3
Connect the black lead to COM, red lead to V/Ω\Omega, and turn the dial to the Ω\Omega range.
The meter is correctly set up to inject reference current and compute resistance from voltage drop.
Placing leads in current (A/mA) jacks or selecting incorrect functions causes measurement failure or errors.
4
Apply probe tips firmly to the two coil terminals and wait for a stable reading.
The multimeter displays the true resistance of the coil winding.
Firm probe pressure minimizes contact resistance and ensures accurate measurement.
5
Evaluate the measured resistance relative to published technical data.
Accurate diagnostic determination of whether the coil is operational, shorted (near 0 Ω0\ \Omega), or open (OL).
A reading matching nominal specifications indicates a good coil, while significant deviations indicate faults.

Anahtar Kavram

Multimeter resistance testing requires a strictly ordered procedure: de-energizing power for safety, isolating the component to eliminate parallel paths, configuring proper meter settings, taking the measurement, and comparing results with specifications.
Tahmini Süre:1m 0s
Soru 1026Soru →

In a direct current (DC) avionics test circuit, a 48 V48\text{ V} power supply is connected in series with a 30 Ω30\text{ }\Omega current-limiting resistor and a 50 Ω50\text{ }\Omega load resistor. What is the electrical power dissipated by the 50 Ω50\text{ }\Omega load resistor, in watts?

Cevabı ve açıklamayı göster

Cevap: 18

Cevap

The power dissipated by the 50 Ω50\text{ }\Omega load resistor is 18 W18\text{ W}.
In a series circuit, the total resistance is the sum of all individual resistances (30 Ω+50 Ω=80 Ω30\text{ }\Omega + 50\text{ }\Omega = 80\text{ }\Omega). With a 48 V48\text{ V} supply, the circuit current is I=48 V80 Ω=0.6 AI = \frac{48\text{ V}}{80\text{ }\Omega} = 0.6\text{ A}. The electrical power dissipated by the 50 Ω50\text{ }\Omega resistor is determined by P=I2R=(0.6 A)2×50 Ω=18 WP = I^2 R = (0.6\text{ A})^2 \times 50\text{ }\Omega = 18\text{ W}.

Adım Adım Çözüm

1
Find the equivalent total resistance of the series circuit
Rtotal=30 Ω+50 Ω=80 ΩR_{\text{total}} = 30\text{ }\Omega + 50\text{ }\Omega = 80\text{ }\Omega
Resistances in a series circuit are directly additive to determine total opposition to current flow.
2
Calculate the total circuit current using Ohm's Law
I=VtotalRtotal=48 V80 Ω=0.6 AI = \frac{V_{\text{total}}}{R_{\text{total}}} = \frac{48\text{ V}}{80\text{ }\Omega} = 0.6\text{ A}
Current is uniform throughout all components connected in a series loop.
3
Calculate the power dissipation in the load resistor using Watt's Law
P=I2×R=(0.6 A)2×50 Ω=0.36 A2×50 Ω=18 WP = I^2 \times R = (0.6\text{ A})^2 \times 50\text{ }\Omega = 0.36\text{ A}^2 \times 50\text{ }\Omega = 18\text{ W}
Power dissipated by a resistor is proportional to the square of the current flowing through it multiplied by its resistance.

Anahtar Kavram

Series circuit current and resistor power dissipation using combined Ohm's Law and Watt's Law (P=I2RP = I^2 R or P=V2RP = \frac{V^2}{R})

Alternatif Yöntem

Find the voltage drop across the load resistor using the voltage divider rule: Vload=48 V×(50 Ω30 Ω+50 Ω)=48×58=30 VV_{\text{load}} = 48\text{ V} \times \left(\frac{50\text{ }\Omega}{30\text{ }\Omega + 50\text{ }\Omega}\right) = 48 \times \frac{5}{8} = 30\text{ V}. Then compute power using P=Vload2Rload=30250=90050=18 WP = \frac{V_{\text{load}}^2}{R_{\text{load}}} = \frac{30^2}{50} = \frac{900}{50} = 18\text{ W}.
Tahmini Süre:1m 15s
Soru 1027Soru →

An electronics technician performs diagnostic checks on various malfunctioning direct-current (DC) systems. Match each electrical troubleshooting symptom or meter reading on the left with its most probable circuit fault condition on the right.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

An ohmmeter test across a de-energized relay coil rated at 250 Ω250\,\Omega measures 0.0 Ω0.0\,\Omega.
A voltmeter measures full source voltage (12 V12\text{ V}) directly across the terminals of a closed switch in an active, non-functioning circuit.
A circuit displays normal source voltage under no-load conditions, but voltage at the load drops drastically below specification when operating under full current draw.
An ohmmeter connected between an isolated appliance's ungrounded positive power lead and its metallic chassis reads 0.0 Ω0.0\,\Omega.

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

The symptom of 0.0 ohms across a 250-ohm coil matches short-circuited coil windings; full source voltage measured across closed switch terminals matches an open circuit from failed switch contacts; voltage dropping severely under load matches a high-resistance or corroded connection; and 0.0 ohms between the ungrounded positive lead and metallic chassis matches a direct ground fault.
Each diagnostic reading correlates directly to fundamental circuit failure modes: a shorted coil eliminates component resistance (0 Ω0\,\Omega); an open switch drops the entire source voltage (12 V12\text{ V}) because current cannot bridge the open gap; a high-resistance joint creates excessive voltage drop only when current flows (V=I×RV = I \times R); and continuity between a 'hot' power lead and the chassis represents a short to ground.

Adım Adım Çözüm

1
Analyze the relay coil resistance reading of 0.0 Ω0.0\,\Omega.
Identifies an internal short circuit.
Inductive components such as relay coils are designed with specific continuous wire resistance. A reading of 0.0 Ω0.0\,\Omega means the insulation between windings broke down, creating a direct short.
2
Analyze the closed switch voltage reading showing full source voltage.
Identifies an open switch fault.
According to Kirchhoff's Voltage Law, an open point in a series circuit drops the entire source voltage because it creates infinite resistance and blocks current, whereas a properly closed switch drops 0 V0\text{ V}.
3
Analyze the loaded vs. unloaded voltage drop behavior.
Identifies a high-resistance connection fault.
When no current flows (I=0I = 0), no voltage is dropped across bad connections (V=0 VV = 0\text{ V}). When load current flows, parasitic resistance drops voltage in proportion to current, starving the load.
4
Analyze the zero-ohm reading between the positive supply rail and metal chassis.
Identifies a direct chassis ground fault.
Conductors intended to carry current must remain insulated from the metal chassis. A 0.0 Ω0.0\,\Omega reading confirms an unintended low-resistance bridge to the chassis frame.

Anahtar Kavram

Circuit fault diagnosis using voltage drop and resistance characteristics for opens, shorts, grounds, and high-resistance faults.
Tahmini Süre:1m 30s
Soru 1028Soru →

During a maintenance check on an emergency backup power system, an ammeter registers a continuous reading of 4 amperes4\text{ amperes} through a primary feeder wire. How many coulombs of electrical charge pass through any given cross-section of this feeder wire in 15 seconds15\text{ seconds}?

Cevabı ve açıklamayı göster

Cevap: 60 coulombs60\text{ coulombs}

Cevap

60 coulombs60\text{ coulombs} of electrical charge pass through the cross-section.
Electric current in amperes measures the rate of charge movement where 1 ampere=1 coulomb per second1\text{ ampere} = 1\text{ coulomb per second}. Multiplying the steady current (4 A4\text{ A}) by the elapsed time (15 s15\text{ s}) gives the total charge transfer: 4 C/s×15 s=60 coulombs4\text{ C/s} \times 15\text{ s} = 60\text{ coulombs}.

Adım Adım Çözüm

1
Identify the relationship between electric current, charge, and time
I=QtI = \frac{Q}{t}, where II is current in amperes, QQ is charge in coulombs, and tt is time in seconds
One ampere is defined as the flow of one coulomb of charge per second (1 A=1 C/s1\text{ A} = 1\text{ C/s}).
2
Rearrange the formula to solve for total charge QQ
Q=I×tQ = I \times t
Multiplying both sides of the rate equation by time isolates the total charge quantity.
3
Substitute the given values into the equation and compute the result
Q=4 A×15 s=60 CQ = 4\text{ A} \times 15\text{ s} = 60\text{ C}
Evaluating the product yields the total accumulated charge that traversed the wire.

Anahtar Kavram

Electric current is the time rate of electric charge transfer through a conductor (1 A=1 C/s1\text{ A} = 1\text{ C/s}).
Tahmini Süre:45s
Soru 1029Soru →

A railway signal monitoring circuit is powered by a 72 V72\text{ V} DC power supply. The circuit consists of three components connected in series: an 85 Ω85\ \Omega relay coil, a 35 Ω35\ \Omega surge-limiting resistor, and an unknown protective resistor RxR_x. If the entire circuit draws a steady current of 0.4 A0.4\text{ A}, what is the resistance of the protective resistor RxR_x in ohms (Ω\Omega)?

Cevabı ve açıklamayı göster

Cevap: 60

Cevap

The resistance of the protective resistor RxR_x is 60 Ω60\ \Omega.
Applying Ohm's Law (RT=VTIR_T = \frac{V_T}{I}) gives a total series resistance of 180 Ω180\ \Omega. Since resistances in series add directly (RT=85 Ω+35 Ω+Rx=120 Ω+RxR_T = 85\ \Omega + 35\ \Omega + R_x = 120\ \Omega + R_x), solving for the unknown yields Rx=180 Ω−120 Ω=60 ΩR_x = 180\ \Omega - 120\ \Omega = 60\ \Omega.

Adım Adım Çözüm

1
Calculate the total circuit resistance (RTR_T) using Ohm's Law.
RT=VsourceItotal=72 V0.4 A=180 ΩR_T = \frac{V_{\text{source}}}{I_{\text{total}}} = \frac{72\text{ V}}{0.4\text{ A}} = 180\ \Omega
In a series circuit, total resistance equals total source voltage divided by total circuit current.
2
Determine the combined resistance of the known series components.
Rknown=Rrelay+Rsurge=85 Ω+35 Ω=120 ΩR_{\text{known}} = R_{\text{relay}} + R_{\text{surge}} = 85\ \Omega + 35\ \Omega = 120\ \Omega
Resistances in a series circuit are directly additive.
3
Subtract the known series resistance from the total circuit resistance to solve for RxR_x.
Rx=RT−Rknown=180 Ω−120 Ω=60 ΩR_x = R_T - R_{\text{known}} = 180\ \Omega - 120\ \Omega = 60\ \Omega
The sum of all individual series resistors must equal the total equivalent resistance (RT=R1+R2+RxR_T = R_1 + R_2 + R_x).

Anahtar Kavram

In a direct-current (DC) series circuit, current is identical through every component (IT=I1=I2=I3I_T = I_1 = I_2 = I_3), and the total equivalent resistance is the arithmetic sum of all individual resistances (RT=R1+R2+⋯+RnR_T = R_1 + R_2 + \dots + R_n).

Alternatif Yöntem

Find the voltage drops across the known components first: Vrelay=0.4 A×85 Ω=34 VV_{\text{relay}} = 0.4\text{ A} \times 85\ \Omega = 34\text{ V} and Vsurge=0.4 A×35 Ω=14 VV_{\text{surge}} = 0.4\text{ A} \times 35\ \Omega = 14\text{ V}. Subtract these from the total source voltage using Kirchhoff's Voltage Law: VRx=72 V−(34 V+14 V)=24 VV_{Rx} = 72\text{ V} - (34\text{ V} + 14\text{ V}) = 24\text{ V}. Then find Rx=VRxI=24 V0.4 A=60 ΩR_x = \frac{V_{Rx}}{I} = \frac{24\text{ V}}{0.4\text{ A}} = 60\ \Omega.
Tahmini Süre:1m 0s
Soru 1030Soru →

When assembling delicate circuitry where components may experience slight movement while cooling, why is eutectic 63/37 solder preferred over 60/40 solder?

Cevabı ve açıklamayı göster

Cevap: It transitions directly between liquid and solid states without passing through an intermediate pasty range.

Cevap

Eutectic 63/37 solder transitions immediately from liquid to solid at a single temperature without an intermediate semi-solid pasty stage.
A eutectic alloy (63/37 tin-lead) possesses the unique property of melting and freezing at a single, specific temperature (361°F / 183°C). Because it changes instantly from liquid to solid with no intermediate slushy or pasty state, any slight movement of leads or vibration during cooling will not compromise the mechanical strength or electrical conductivity of the joint.

Adım Adım Çözüm

1
Analyze the metallurgical distinction between eutectic (63% tin / 37% lead) and non-eutectic (60% tin / 40% lead) solder alloys.
Standard 60/40 solder melts over a range between 361°F (183°C) and 374°F (190°C), creating a plastic or 'pasty' state during cooling.
Non-eutectic formulations contain varying phases during thermal transition.
2
Evaluate the effect of workpiece vibration or movement during the alloy's solidification phase.
Movement while solder is in its pasty range fractures the forming crystalline matrix, creating a high-resistance 'disturbed' or cold solder joint.
Physical displacement during partial crystallization disrupts atomic bonding across the joint.
3
Identify the primary operational benefit of the eutectic 63/37 composition.
Because 63/37 solidifies instantaneously at 361°F (183°C) with zero pasty range, the joint locks into place immediately upon reaching this temperature.
Eliminating the pasty window significantly minimizes defects when soldering delicate or hand-held components.

Anahtar Kavram

Eutectic vs. Non-Eutectic Solder Phase Transitions and Joint Integrity
Tahmini Süre:1m 0s
Soru 1031Soru →

An industrial control module features a 36 V36\text{ V} DC source driving a resistor network. The configuration consists of a 150 Ω150\ \Omega input resistor (R1R_1) wired in series with a parallel pair of 300 Ω300\ \Omega load resistors (R2R_2 and R3R_3). A test point (TP1) is located at the junction separating R1R_1 from the parallel pair.

Under nominal conditions, the circuit draws 120 mA120\text{ mA} from the source, and a multimeter reads 18 V18\text{ V} at TP1 with respect to ground.

A system failure occurs, and a technician records new diagnostic readings:
- The voltage at TP1 with respect to ground is now 36 V36\text{ V}.
- The total current drawn from the 36 V36\text{ V} source is now 240 mA240\text{ mA}.

Based on these diagnostic readings, which of the following component failures has occurred?

Cevabı ve açıklamayı göster

Cevap: R1R_1 has suffered an internal short circuit.

Cevap

The component failure is that R1R_1 has suffered an internal short circuit.
For the voltage at TP1 to equal the source voltage (36 V36\text{ V}), there must be no voltage drop across the series resistor R1R_1. This occurs either when there is no current flowing, or when R1R_1 has zero resistance. Because the circuit is drawing 240 mA240\text{ mA} (a higher-than-normal current), the circuit is not open. Therefore, R1R_1 must have zero resistance due to an internal short circuit. When R1R_1 is shorted, the total circuit resistance drops to just the 150 Ω150\ \Omega equivalent resistance of the parallel pair, which mathematically accounts for the exactly 240 mA240\text{ mA} current draw (36 V/150 Ω36\text{ V} / 150\ \Omega).

Adım Adım Çözüm

1
Analyze the voltage reading at TP1 during the fault.
TP1 measures 36 V36\text{ V}, which equals the source voltage.
This indicates there is zero voltage drop across R1R_1. This can only happen if no current is flowing through R1R_1 (an open circuit downstream) or if R1R_1 has zero resistance (a short circuit).
2
Analyze the total current reading during the fault.
Total current is 240 mA240\text{ mA}, which is twice the normal operating current.
Since current is flowing (and is higher than normal), the circuit cannot be open. Therefore, the zero voltage drop across R1R_1 must be caused by a short circuit across R1R_1 itself.
3
Verify the shorted R1R_1 hypothesis mathematically using Ohm's Law.
If R1=0 ΩR_1 = 0\ \Omega, total resistance is 300 Ω/2=150 Ω300\ \Omega / 2 = 150\ \Omega. Total current = 36 V/150 Ω=0.24 A36\text{ V} / 150\ \Omega = 0.24\text{ A} (240 mA240\text{ mA}). Voltage at TP1 = 36 V−(0.24 A×0 Ω)=36 V36\text{ V} - (0.24\text{ A} \times 0\ \Omega) = 36\text{ V}.
Both mathematical results precisely match the technician's fault measurements, confirming R1R_1 is shorted.

Anahtar Kavram

Series-Parallel Circuit Troubleshooting and Ohm's Law
Soru 1032Soru →

An electronics technician is servicing power supplies and control circuits containing various protection components. Match each circuit protective device or mechanism on the left with its primary operational principle on the right.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

Magnetic trip mechanism in a circuit breaker
Bimetallic strip in a thermal circuit breaker
Polymeric positive temperature coefficient (PPTC) resettable fuse
Transient voltage suppression (TVS) diode

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

Magnetic trip mechanism matches with electromagnetic flux pulling an armature for instantaneous tripping; Bimetallic strip matches with progressive bending from thermal expansion during prolonged overcurrents; PPTC resettable fuse matches with transitioning to high resistance upon I2RI^2R heating and self-resetting; TVS diode matches with avalanche breakdown to clamp fast transient overvoltage spikes.
Each protective device is correctly paired with its operating physics: magnetic elements react instantly to short circuits via electromagnetic attraction; bimetallic strips bend slowly in response to resistive heat during continuous overloads; PPTC devices restrict current by increasing resistance when heated and recover when cool; and TVS diodes suppress voltage spikes through fast avalanche breakdown in parallel with the load.

Adım Adım Çözüm

1
Distinguish between overcurrent protective devices and transient overvoltage suppression devices.
Identify that circuit breaker elements and PPTC fuses protect against excessive current flow, whereas TVS diodes protect against voltage transients.
Protective devices function either as series current limiters/interrupts or parallel voltage clamps.
2
Differentiate between the dual trip mechanisms of thermal-magnetic circuit breakers.
The magnetic solenoid provides instantaneous response to large short-circuit currents, while the bimetal strip provides an inverse-time response to moderate sustained overloads.
Magnetic tripping prevents catastrophic equipment damage during direct shorts, whereas thermal tripping prevents wire insulation overheating from prolonged overloads.
3
Examine the solid-state behavior of PPTC fuses and TVS diodes.
PPTC devices rely on temperature-dependent polymer resistance expansion to limit overcurrent, while TVS diodes rely on p-n junction avalanche breakdown to shunt transient overvoltage.
Associating each solid-state component with its physical trigger establishes the correct pairs.

Anahtar Kavram

Operational Principles of Overcurrent and Overvoltage Protective Devices
Tahmini Süre:1m 15s
Soru 1033Soru →

Which of the following materials is classified as a ferromagnetic substance that is strongly attracted to a magnetic field?

Cevabı ve açıklamayı göster

Cevap: Nickel

Cevap

Nickel is a ferromagnetic material that is strongly attracted to a magnetic field.
Ferromagnetic materials such as iron, cobalt, and nickel have permanent atomic magnetic dipoles that align easily with an external magnetic field, creating strong magnetic attraction.

Adım Adım Çözüm

1
Identify the characteristic properties of ferromagnetic materials.
Ferromagnetic substances contain atomic magnetic domains that readily align with an external field, resulting in strong magnetic attraction.
Ferromagnetism is the basic mechanism by which certain materials form permanent magnets or are strongly attracted to magnets.
2
Evaluate the listed materials to identify the ferromagnetic element.
The primary ferromagnetic elements at room temperature are iron, cobalt, and nickel.
Common conductors like copper and aluminum, as well as insulators like mica, do not exhibit ferromagnetism.

Anahtar Kavram

Ferromagnetic materials and magnetic permeability
Tahmini Süre:35s
Soru 1034Soru →

A technician measures a steady current of 50 mA50\text{ mA} flowing through a 120 Ω120\ \Omega fixed resistor in a signal conditioning module. What is the voltage drop across the resistor?

Cevabı ve açıklamayı göster

Cevap: 6 V6\text{ V}

Cevap

6 V6\text{ V}
According to Ohm's law, the voltage drop across a component is determined by multiplying current by resistance (V=I×RV = I \times R). Converting 50 mA50\text{ mA} to 0.05 A0.05\text{ A} and multiplying by 120 Ω120\ \Omega gives 6 V6\text{ V}.

Adım Adım Çözüm

1
Convert the current from milliamperes (mA) to amperes (A).
50 mA=0.05 A50\text{ mA} = 0.05\text{ A}
Standard electrical formulas require current in amperes.
2
Apply Ohm's law formula for voltage (V=I×RV = I \times R).
V=0.05 A×120 Ω=6 VV = 0.05\text{ A} \times 120\ \Omega = 6\text{ V}
Voltage across a resistor equals the product of current and resistance.

Anahtar Kavram

Ohm's Law states that voltage is equal to current multiplied by resistance (V=I×RV = I \times R).
Tahmini Süre:45s
Soru 1035Soru →

Fill in the blanks to complete the statement describing variable resistor terminology.

Aşağıdaki boşlukları doldurun

A three-terminal variable resistor commonly used to create an adjustable voltage divider is called a , and the internal adjustable contact that moves across the resistive track is called the .
Cevabı ve açıklamayı göster

Cevap

blank_1: potentiometer; blank_2: wiper
A potentiometer is a three-terminal variable resistor widely used to provide an adjustable voltage division in electronic circuits. The two outer terminals connect across the full resistive element, while the center movable contact, called the wiper, adjusts the output voltage based on its mechanical position.

Adım Adım Çözüm

1
Identify the standard three-terminal variable resistor component
A potentiometer (often abbreviated 'pot') is a three-terminal variable resistor configured to divide voltage across its resistive track.
By definition in basic electronics, a three-terminal variable resistor used for voltage division is designated as a potentiometer.
2
Identify the movable mechanical contact mechanism
The sliding contact that traverses the resistive material to tap off a portion of the total resistance is called the wiper.
The standard technical term for the adjustable middle contact of a potentiometer or rheostat is the wiper.

Anahtar Kavram

Potentiometer structure and terminology
Tahmini Süre:30s
Soru 1036Soru →

When servicing an industrial control cabinet, a technician must safely remove a cylindrical cartridge fuse from its spring mounting clips. Which hand tool is specifically manufactured from non-conductive insulating material to perform this task without creating an electrical shock hazard?

Cevabı ve açıklamayı göster

Cevap: Fuse puller

Cevap

Fuse puller
A fuse puller is manufactured from high-dielectric insulating materials such as vulcanized fiber or molded nylon, featuring specially contoured jaws that clamp securely onto cylindrical cartridge fuses without conducting electricity.

Adım Adım Çözüm

1
Identify the electrical safety requirement for removing cartridge fuses from mounting clips.
Cartridge fuses reside in spring tension clips that may remain energized; using metal hand tools creates a direct shock and phase-to-ground fault hazard.
Standard metal hand tools conduct electric current directly to the technician's hands.
2
Select the dedicated hand tool constructed from dielectric, non-conductive material.
A fuse puller provides mechanical leverage and notched jaws to firmly grip cylindrical fuses while insulating the operator completely from electrical potential.
Dedicated fuse pullers ensure compliance with safety protocols by preventing current flow through the user.

Anahtar Kavram

Non-conductive electrical hand tools (fuse pullers) protect technicians from shock and short circuits when installing or extracting cartridge fuses.
Tahmini Süre:35s
Soru 1037Soru →

An electronics technician measures a power dissipation of 20 W20\text{ W} across a 500 Ω500\ \Omega test resistor in a direct-current circuit. What is the electrical current flowing through this resistor in milliamperes (mA\text{mA})?

Cevabı ve açıklamayı göster

Cevap: 200 mA200\text{ mA}

Cevap

200 mA200\text{ mA}
According to Watt's Law, power dissipated in a resistive load is P=I2RP = I^2 R. Rearranging to solve for current gives I=PR=20 W500 Ω=0.04=0.2 AI = \sqrt{\frac{P}{R}} = \sqrt{\frac{20\text{ W}}{500\ \Omega}} = \sqrt{0.04} = 0.2\text{ A}. Converting amperes to milliamperes gives 0.2 A×1000 mA/A=200 mA0.2\text{ A} \times 1{}000\text{ mA/A} = 200\text{ mA}.

Adım Adım Çözüm

1
Identify known parameters and select the Watt's Law formula relating power, resistance, and current.
P=20 WP = 20\text{ W}, R=500 ΩR = 500\ \Omega, and P=I2RP = I^2 R
The circuit power and resistance are given, and current is the unknown quantity.
2
Rearrange the formula to solve for current (II) and substitute the given values.
I=PR=20 W500 Ω=0.04=0.2 AI = \sqrt{\frac{P}{R}} = \sqrt{\frac{20\text{ W}}{500\ \Omega}} = \sqrt{0.04} = 0.2\text{ A}
Isolating II requires dividing power by resistance and taking the square root.
3
Convert the calculated current from amperes to milliamperes.
0.2 A×1000 mA/A=200 mA0.2\text{ A} \times 1{}000\text{ mA/A} = 200\text{ mA}
The question asks for the final answer in milliamperes.

Anahtar Kavram

Watt's Law relates power, current, and resistance via P=I2RP = I^2 R, which rearranges to I=PRI = \sqrt{\frac{P}{R}}.

Alternatif Yöntem

First compute the voltage drop across the resistor using V=P×R=20 W×500 Ω=10000=100 VV = \sqrt{P \times R} = \sqrt{20\text{ W} \times 500\ \Omega} = \sqrt{10{}000} = 100\text{ V}. Then apply Ohm's Law to find current: I=VR=100 V500 Ω=0.2 A=200 mAI = \frac{V}{R} = \frac{100\text{ V}}{500\ \Omega} = 0.2\text{ A} = 200\text{ mA}.
Tahmini Süre:1m 0s
Soru 1038Soru →

An audio technician is designing a passive crossover network and installs an inductor in series with a low-frequency woofer. Which of the following best explains why the inductor is used in this configuration?

Cevabı ve açıklamayı göster

Cevap: It opposes high-frequency alternating currents while allowing low-frequency signals to pass easily.

Cevap

The inductor opposes high-frequency alternating currents while allowing low-frequency signals to pass easily.
An inductor generates an opposing electromotive force (back EMF) that increases with the rate of change of current. Because inductive reactance is calculated as XL=2πfLX_L = 2\pi f L, opposition rises with higher signal frequencies. Consequently, placing an inductor in series with a woofer permits low-frequency audio to pass with minimal attenuation while attenuating unwanted high frequencies.

Adım Adım Çözüm

1
Identify the relationship between frequency and inductor behavior.
Inductive reactance is defined by the formula XL=2πfLX_L = 2\pi f L, where ff is frequency and LL is inductance.
Understanding how an inductor's opposition changes with frequency determines which signals it blocks or passes.
2
Analyze circuit operation at low versus high audio frequencies.
At low audio frequencies (ff is small), XLX_L is low, presenting almost zero opposition. At high audio frequencies (ff is large), XLX_L is high, presenting strong opposition to current flow.
This behavior creates a low-pass filter when placed in series with a speaker load.
3
Match the electrical characteristics to the speaker application.
The series inductor acts as a low-pass filter (choke), directing bass signals to the woofer while blocking treble frequencies.
Woofers are designed strictly for low-frequency sound reproduction.

Anahtar Kavram

Inductive reactance (XL=2πfLX_L = 2\pi f L) increases with frequency, allowing an inductor to block high-frequency AC signals while allowing low-frequency signals to pass.
Tahmini Süre:1m 0s
Soru 1039Soru →

During which stroke of a four-stroke internal combustion engine do both valves remain closed while the spark plug ignites the compressed air-fuel mixture to push the piston downward?

Cevabı ve açıklamayı göster

Cevap: Power stroke

Cevap

The power stroke is the phase where ignition occurs and expanding combustion gases force the piston downward with both valves closed.
During the power stroke (also called the combustion or expansion stroke), both the intake and exhaust valves are closed to seal the combustion chamber. Ignition of the compressed air-fuel mixture creates rapid expansion, forcing the piston down the cylinder bore and transferring mechanical power to the crankshaft.

Adım Adım Çözüm

1
Identify the specific mechanical events described in the question
Both valves are closed, ignition occurs at the spark plug, and high pressure drives the piston downward.
This step converts the fuel's chemical energy into usable mechanical work.
2
Match these operating conditions to the correct stage of the four-stroke cycle
Power stroke
The four strokes are intake (intake valve open, downward travel), compression (valves closed, upward travel), power (valves closed, ignition, downward travel), and exhaust (exhaust valve open, upward travel).

Anahtar Kavram

Four-stroke internal combustion engine cycle phases
Tahmini Süre:45s
Soru 1040Soru →

A technician is using a digital multimeter (DMM) set to the resistance (Ω\Omega) and continuity modes to troubleshoot de-energized components on an industrial electrical bench. Match each multimeter measurement reading on the left with its corresponding diagnostic circuit condition on the right.

Soldaki öğeye tıklayın, sonra eşleşen sağdaki öğeye tıklayın

Öğeler

Probing across the terminal contacts of an unactuated, de-energized normally open (NO) control switch displays 'O.L' (>40 MΩ> 40\text{ M}\Omega).
Probing between the main AC line power terminal and the metal equipment chassis of an isolated motor controller displays 0.1 Ω0.1\,\Omega.
Probing across the isolated terminals of an electric motor stator coil rated at 3.5 Ω3.5\,\Omega displays 'O.L' with no audible continuity tone.
Probing across the unpowered filament terminals of an incandescent panel indicator lamp displays 18 Ω18\,\Omega.

Eşleşmeler

Cevabı ve açıklamayı göster

Cevap

The normally open switch reading 'O.L' matches the normal open-circuit state for separated contacts; the AC line-to-chassis reading of 0.1 Ω0.1\,\Omega matches the severe line-to-ground short circuit fault; the motor coil reading 'O.L' matches the burned-out internal open winding failure; and the indicator lamp reading 18 Ω18\,\Omega matches the normal continuous conductive path for an intact resistive load.
Each multimeter reading directly correlates to the internal electrical state of the component: an open contact set produces infinite resistance ('O.L'), an unintended low-resistance connection between hot conductors and frame ground represents a dead short (0.1 Ω0.1\,\Omega), a severed coil wire destroys continuity ('O.L'), and a continuous resistive filament yields its nominal cold resistance (18 Ω18\,\Omega).

Adım Adım Çözüm

1
Evaluate the normally open (NO) switch measurement
Display reads 'O.L' (>40 MΩ> 40\text{ M}\Omega)
When de-actuated, NO switch contacts are physically separated by air (an insulator), so infinite resistance is the expected normal condition.
2
Evaluate the AC line terminal to chassis ground measurement
Display reads 0.1 Ω0.1\,\Omega
Power conductors should be electrically isolated from structural metal enclosures. A near-zero reading indicates a dangerous short circuit / ground fault.
3
Evaluate the motor stator winding measurement against its nominal 3.5 Ω3.5\,\Omega rating
Display reads 'O.L' with no continuity beep
Because the coil should form a continuous low-resistance inductive path, an over-limit reading proves the wire has melted or fractured into an open circuit.
4
Evaluate the incandescent lamp filament measurement
Display reads 18 Ω18\,\Omega
An intact metal filament has low finite resistance at ambient temperature, confirming circuit continuity and normal component health.

Anahtar Kavram

Interpreting digital multimeter resistance and continuity display values (zero ohms, nominal ohms, over-limit / O.L) to distinguish between normal component states, open-circuit faults, and short circuits.
Tahmini Süre:1m 30s
ÖncekiSayfa 52 / 261Sonraki
Tüm alıştırma soruları — Armed Services Vocational Aptitude Battery (ASVAB) | Examkin